Installation

5.1

Configuring the siren

5.2

Powering up the siren

Note: If you install the siren for the first time, it will automatically power up in service mode. You cannot switch the siren out of
service mode and into operating mode until at least one remote control or remote keypad is linked to it.
1.
Remove the screws.
2.
Remove the battery cover.
3.
Set switch 5 to the required position.
Without control panel
(single zone)
With separate control panel
4.
Set switch 1 to limit the maximum period for which the external
siren will sound.
Without control panel
(single zone)
With separate control panel
5.
Set switch 2 to enable or disable the anti-jamming detection when
using the siren without control panel.
ON
enabled
OFF
disabled
6.
Set switch 3 to enable or disable the siren during an alarm.
ON
enabled
OFF
disabled
7.
Set switch 4 to enable or disable the beeps when the siren receives
signals from the remote control or the remote keypad.
ON
enabled
OFF
disabled
1.
Connect the initial power-up battery to the connection terminal.
2.
Connect the rechargeable main battery to the connection terminal.
5
ON (siren)
OFF (control panel)
ON (3 min) / OFF (1 min)
ON (10 min) / OFF (3 min)