FUNCTIONAL DESCRIPTION
Always be sure that the tool is
WARNING:
switched off and the battery cartridge is removed
before adjusting or checking function on the tool.
Failure to switch off and remove the battery cartridge
may result in serious personal injury from accidental
start-up.
Installing or removing battery cartridge
Always switch off the tool before
CAUTION:
installing or removing of the battery cartridge.
Hold the tool and the battery car-
CAUTION:
tridge firmly when installing or removing battery
cartridge. Failure to hold the tool and the battery
cartridge firmly may cause them to slip off your hands
and result in damage to the tool and battery cartridge
and a personal injury.
► Fig.2: 1. Red indicator 2. Button 3. Battery cartridge
To remove the battery cartridge, slide it from the tool
while sliding the button on the front of the cartridge.
To install the battery cartridge, align the tongue on the
battery cartridge with the groove in the housing and slip
it into place. Insert it all the way until it locks in place
with a little click. If you can see the red indicator on the
upper side of the button, it is not locked completely.
Always install the battery cartridge
CAUTION:
fully until the red indicator cannot be seen. If not,
it may accidentally fall out of the tool, causing injury to
you or someone around you.
Do not install the battery cartridge
CAUTION:
forcibly. If the cartridge does not slide in easily, it is
not being inserted correctly.
Tool / battery protection system
The tool is equipped with a tool/battery protection sys-
tem. This system automatically cuts off power to the
motor to extend tool and battery life. The tool will auto-
matically stop during operation if the tool or battery is
placed under one of the following conditions:
Status
On
Overload
Overheat
Over
discharge
Indicator lamps
Off
Blinking
Overload protection
If the tool is overloaded by entangled weeds or other
debris,
and the middle indicators start blinking and
the tool automatically stops.
In this situation, turn the tool off and stop the application
that caused the tool to become overloaded. Then turn
the tool on to restart.
Overheat protection for tool or battery
When a over heating occurs, all speed indicators blink.
If the overheating occurs, the tool stops automatically.
Let the tool and/or battery cool down before turning the
tool on again.
Overdischarge protection
When the battery capacity becomes low, the tool stops
automatically and
If the tool does not operate even when the switches are
operated, remove the batteries from the tool and charge
the batteries.
Indicating the remaining battery capacity
Only for battery cartridges with the indicator
► Fig.3: 1. Indicator lamps 2. Check button
Press the check button on the battery cartridge to indi-
cate the remaining battery capacity. The indicator lamps
light up for a few seconds.
Indicator lamps
Lighted
NOTE: Depending on the conditions of use and the
ambient temperature, the indication may differ slightly
from the actual capacity.
Main power switch
Always turn off the main power
WARNING:
switch when not in use.
To stand by the tool, press the main power button until
the main power lamp lights up. To turn off, press the
main power button again.
► Fig.4: 1. Main power button
9 ENGLISH
indicator blinks.
Off
Blinking
75% to 100%
malfunctioned.
Remaining
capacity
50% to 75%
25% to 50%
0% to 25%
Charge the
battery.
The battery
may have