Message
LEARNING OK
TIME OUT
ID DUPLICATE
2.
Enabling and disabling the remote keypad (KEYPAD WORK)
You can enable and disable a remote keypad.
3.
Deleting the remote control (DEL KEYPAD)
You can delete the settings of the remote keypad from the control panel.
6.2.2.16
Linking the control panel to the Spectra lighting receiver (LINK PANEL TO SPECTRA) (optional)
When the Spectra receiver is in test mode, press the
6.2.2.17
Lighting setup for Spectra lighting receiver (LIGHTING SETUP) (optional)
You can set the operation mode (OPERATION MODE) and the lamp-on time (LAMP-ON TIME) for the Spectra lighting receiver.
If the control panel is linked to a Spectra lighting receiver and the Spectra lighting control is enabled, any alarm condition
(except fire alarms) will switch the linked lighting on for the set light-on duration.
Note: You can only set the start time and stop time from the GlobalGuard PC setup software.
If the Spectra lighting is configured as 24-hour, the lights will be triggered at any time an alarm occurs. If the Spectra lighting is
configured as time-controlled, the lights will only be triggered if the alarm occurs before the programmed stop time or after the
programmed start time. If the alarm occurs between the stop time and the start time, the lights will not be triggered.
6.2.2.18
Language setup
You can set the display language for the control panel.
Note: The control panel may only display the English language. The German language is subject to be added in the near future.
6.2.3
Security detector zone setup (SECURITY DETECTOR ZONE)
PROGRAM MODE
3. SECURITY DETECTOR
ZONE
Wireless detector
zones:
Wired detector zones:
The ID code was learned by the control panel successfully.
If you do not press the buttons on the remote keypad within 60 seconds,
a time-out will occur.
The same ID code was learned by the control panel beforehand.
button to link the control panel to the Spectra lighting receiver.
3-1 WIRELESS
INPUT (01-32)
DETECTOR ZONE
DETECTOR ZONE
3-2 WIRED DETECTOR
INPUT (33-36)
ZONE
DETECTOR ZONE
19
Meaning
:1 LEARNING ID
SEND CODE. WAITING 30S...
:1 WIRED ZONE
:2 LOCATION
NONE / FRONT DOOR / BACK DOOR / PATIO
DOOR / DINING ROOM / LIVING ROOM / LOUNGE
/ STUDY / PLAY ROOM / KITCHEN / UTILITY ROOM
/ HALL / LANDING / BEDROOM 1 / BEDROOM 2 /
BEDROOM 3 / BEDROOM 4 / BEDROOM 5 / SHED
/ GARAGE / PIR / MAG / SMOKE 1 / SMOKE 2 /
SMOKE 3
:3 MODEL TYPE
PIR DETECTOR / DOOR CONTACT / FIRE/SMOKE /
FLOOD DETECTOR / GAS DETECTOR / CO
DETECTOR / EMERGENCY UNIT
:4 SECURITY TYPE
INTRUDER / 24 HR INTRUDER / FIRE / TEST /
PANIC/PA
:5 CHIME MODE
SELECT ON>* / OFF>#
:6 PART-ARM-I
SELECT ON>* / OFF>#
:7 PART-ARM-II
SELECT ON>* / OFF>#
:8 DETECTOR STATUS
SELECT ON>* / OFF>#
:9 DETECTOR REMOVE
SELECT YES>*/ NO>#
:10 SIREN AT TRIGGER
SELECT ON>* / OFF>#
:11 ENTRY DELAY
SELECT ON>* / OFF>#