Additional Wired Door/Window Contact Detector; Testing And Programming; Test Mode (Test Mode); Walk Test (Walk Test) - Honeywell FRIEDLAND FGGK Serie Manual De Instrucciones

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 134
5.10

Additional wired door/window contact detector

6

Testing and programming

6.1

Test mode (TEST MODE)

1.
Make sure that the system is in disarm mode.
2.
Press the
button.
3.
Enter the 4-digit PIN code (User).
4.
Press the
button.
TEST MODE
6.1.1

Walk test (WALK TEST)

The control panel has a built-in test facility to enable you to test the siren at any time. It is recommended to test your system at
regular intervals, but at least once per three months.
Before starting the test, make sure that:
there is no movement for 3 minutes in any area protected by a PIR movement detector.
all doors/windows protected by a door/window contact detector are closed.
all battery covers and housings are installed correctly.
WALK TEST
RF ENVIRONMENT
SPECTRA LIGHTING TEST
WIREFREE SIREN SERVICE OFF
WIREFREE SIREN SERVICE ON
ALARM TEST
If an additional wired door/window contact detector is
required, wire the detector to the terminal block (1) in the
battery compartment. A cable entry cut-out is provided next
to the terminal block in the battery cover.
Connect the wired door/window contact detector using a
maximum length of 1.5 metres of any of the following:
6-core alarm cable
2-core bell wire (min. 6 x 0.2 mm)
2-core 24AWG wire
Use switch SW3 (2) to enable or disable the internal and
external wired magnetic door/window contact detectors:
Position
Function
Top
Only the internal door/window contact
detector is set to the on position.
Bottom
Both the internal and external
door/window contact detectors are set to
the on position.
If you use two door/window contact detectors for internal
and external connections simultaneously, only one activation
event will be counted if one of the contacts is opened. If one
door/window contact detector is left open and the other
closed door/window contact detector is opened, an
activation event will be counted.
If you do not use the external door/window contact
detector, set switch SW3 to the top position to make sure
that the detector operates correctly.
WAITING...
TEST RF ENVIRONMENT
LIGHTS ON FOR 5S. STOP>ESC.
SERVICE OFF. WAIT...
SERVICE ON. WAIT...
RELAY TEST
WIREFREE SIREN TEST
HARDWIRE SIREN TEST
13
RELAY ON FOR 5S. STOP>ESC.
SIREN ON FOR 5S. STOP>ESC.
SIREN ON FOR 5S. STOP>ESC.