EN
3
Heat pipes or fittings by pressing the side to
be welded against the welding plate with the
required contact pressure.
Connecting the pipes or fittings:
• d 32 mm only on the jointing guide.
• d 40–75 mm on the jointing guide or with
the welding machine.
• d 90–315 mm only with the welding
machine.
4
To achieve a high-tensile joint between
pipes and fittings, apply even pressure to
bond the pipes or fittings together
immediately after heating.
14
Maintenance
Maintenance regulations
• Repair work may only be performed by
authorised repair shops.
• The complete welding plate must be sent for
repair in a suitable transport container.
• The addresses of authorised repair shops can be
requested from the Geberit sales companies.
Interval
Maintenance work
Regularly
▶ Examine the welding plate for
(before use, at
externally visible defects and
the start of the
damage.
working day)
▶ Clean the welding plate.
5866419979-1 © 12-2018