DECLARATION OF CONFORMITY
This product is marked
2006/95/CE
– Low voltage no.
– Electromagnetic compatibility no. 89/336 ECC, 92/31 EEC
and 93/68 EEC.
This declaration will become void in case of misuse and/or non
observance though partial of manufacturer's installation and/or
operating instructions.
F-GAS Regulation (EC) No. 842/2006
Do not vent R410A into atmosphere: R410A is a fluorinated
greenhouse gas, covered by Kyoto Protocol, with a Global
Warming Potential (GWP) = 1975.
OPERATING LIMITS
L
Cooling Maximum conditions
Outdoor temperature : 43°C D.B.
Room temperature
: 32°C D.B. / 23°C W.B.
L
Cooling Minimum conditions
Outdoor temperature : 19°C D.B.
Room temperature
: 19°C D.B. / 14°C W.B.
L
Heating Maximum conditions
Outdoor temperature : 24°C D.B. / 18°C W.B.
Room temperature
: 27°C D.B.
L
Heating Minimum conditions
Outdoor temperature : –15°C W.B.
Room temperature
: 16°C B.S.
ACCESSORY FOR UNDER - CEILING OR WALL INSTALLATION (ALREADY INSTALLED)
PARTS
BRACKET
WASHER - SPRING WASHER
PARTS
FIGURE
RAWL PLUG
CLAMPER
REMOTE CONTROL
AAA ALKALINE
BATTERY
REMOTE CONTROL
UNIT HOLDER
INSTALLATION INSTRUCTIONS
– Split system air conditioner –
This air conditioner uses the new refrigerant R410A.
as it satisfies Directives:
.
FIGURE
ACCESSORIES SUPPLIED WITH THE UNIT
Q.TY
PARTS
TAPPING
4
SCREW 4x30
FULL SCALL
1
DIAGRAM
1
BRACKET
SIDE PANELS
2
(LEFT AND RIGHT)
1
37.4196.131.0
Model Combinations
Combine indoor and outdoor units only as listed below.
Indoor Units
SAP-FTRV126EH
SAP-FTRV186EH
SAP-FTRV246EH
FOR "MULTI SPLIT" INSTALLATION SEE "MULTI DC INVERTER
COMBINATIONS TABLE"
Power Supply:
220 - 240 V ~ 50 Hz
WARNING
Read the yellow instruction sheet attached to the outdoor
units.
Tools required for installation (not supplied)
11. Standard screwdriver
12. Phillips head screwdriver
13. Knife or wire stripper
14. Tape measure
15. Level
16. Sabre saw or key hole
saw
17. Hacksaw
18. Core bits ø 5
Q.TY
PARTS
2
BOLT M8
4
FIGURE
Q.TY
4
1
1
2
©SANYO 2008
Outdoor Units
SAP-CRV126EH
SAP-CRV186EH
SAP-CRV246EH
19. Hammer
10. Drill
11. Tube cutter
12. Tube flaring tool
13. Torque wrench
14. Adjustable wrench
15. Reamer (for reburring)
16. Hex. key
FIGURE
PARTS
FIGURE
TAPPING
SCREW 4,2x9,5
DRAIN
ELBOW *
DRAIN
CAP *
CUSHION
RUBBER *
*
Packed in the outdoor unit.
EG
I
F
D
E
P
GR
Q.TY
4
Q.TY
4
1
4
4