English - i.safe MOBILE IS530.M1 Manual Del Usuario

Ocultar thumbs Ver también para IS530.M1:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 8

ENGLISH

EX MARKINGS
ATEX:
I M1 Ex ia I Ma IP64
II 2G Ex ib IIC T4 Gb
II 2D Ex ib IIIC T135°C Db IP6X
EU Type Examination Certificate:
EPS 19 ATEX 1 126 X
CE-designation:
2004
IECEx:
Ex ia I Ma IP64
Ex ib IIC T4 Gb
Ex ib IIIC T135°C Db IP6X
IECEx Certificate: IECEx EPS 19 .0062X
EX-RELEVANT SAFETY REGULATIONS
Use of this device assumes that the operator observes the conventional safety regulations and
has read and understood manual, safety instructions and certificate .
The following safety regulations must also be complied with:
Inside ex-hazardous areas the covers of all interfaces must be closed .
To ensure the IP-protection, it has to be ensured that all gaskets are present
and functional . There must be no large gap between the two halves of the housing .
The device may only be charged outside ex-hazardous areas using the i.safe PROTECTOR 2.0
or i.safe PROTECTOR 3.0 USB-cable or other equipment approved by i.safe MOBILE GmbH .
The device may only be used in zones 1, 21, 2, 22, M1 or M2 .
The device may only be charged at ambient temperatures between +5°C . . . +35°C .
The device may not be exposed to any aggressive acids or alkalis .
The device shall be protected against the effects of oils, greases and hydraulic fluids .
The device must be protected from impacts with high impact energy, against excessive UV
light emission and high electrostatic processes .
The ISM interface of the IS530.M1 can be used within hazardous areas with approved ac-
cessories . For ISM interface use, the i.safe MOBILE headset IS-HS1.1 and the trigger handle
IS-TH1xx.M1 are approved . If the ISM interface is not used, it must be securely closed by the
cover provided for this purpose .
The SD cards type IS-SD164.1 and IS-SD1128.1 may be used in the corresponding slot in the
hazardous area .
SIM cards which comply with the intrinsic safety entity parameters, may be used in the corres-
ponding slots in the hazardous area .
INFORMATION CONCERNING SAR CERTIFICATION
(SPECIFIC ABSORBATION RATE)
Maximum SAR values for this model and the conditions under which these were determined:
SAR (head)
SAR (body - worn)
ANZEx:
Ex ia I Ma IP64
Ex ib IIC T4 Gb
Ex ib IIIC T135°C Db IP6X
ANZEx Certificate: ANZEx 20 .2002X
Temperature range:
-20°C ... +60°C
Manufactured by:
i.safe MOBILE GmbH
i_Park Tauberfranken 10
97922 Lauda-Koenigshofen
Germany
0 .81 W/kg