INPUT/OUTPUT - DESCRIPTION AND EXAMPLES OF WIRING
F
Inputs
Pin Name
Rmt Start
1
(remote start)
Reverse
2
(remote reverse)
3
Enable A
4
Enable B
5
Enable REV
6
Reset Batch
7
Pset 1
8
Pset 2
9
Pset 3
10 Pset 4
11
Pset 5
12 No Ack
Rev PRE RUN
13
(Pre-run reverse)
14 Com
Outputs
Pin Name
Description
1
OK
Activated when the tightening
report is "OK".
2
Gnd
-
3
NOK
Activated when the tightening
report is "NOK".
4
Gnd
-
5
OK batch
Activated when the batch is
complete.
6
Gnd
-
7
Run Fwd
Activated when the tool is
running forward.
8
Gnd
-
9
Run Bwd
Activated when the tool is
running backwards.
10 Gnd
-
11
VDC Out
24 VDC
12 Gnd
V-
13 -
N/A
14 -
N/A
Description
To run the tool forward.
To run the tool in reverse.
To allow the tool A to run if enabled.
To stop immediately the tool if disabled.
To allow the tool B to run if enabled.
To stop immediately the tool if disabled.
To allow the tool to reverse if enabled.
To reset the batch count to zero.
To select Pset 1.
To select Pset 2.
To select Pset 3.
To select Pset 4.
To select Pset 5.
To unlock the tool when the report is NOK.
To allow the tool to run in reverse mode when the "Pre-run
reverse" feature is activated.
Common ground.
12 / 172
Connection
Signal is "on" until next tool start with a
minimum time of 0.5 sec.
"On": short pin 1 - Pin 2.
Signal is "on" until next tool start with a
minimum time of 0.5 sec.
"On": short pin 3 - Pin 4.
Signal is "on" until next tool start with a
minimum time of 0.5 sec.
"On": short pin 5 - Pin 6.
Signal is "on" as long as the tool is running
forward.
"On": short pin 7 - Pin 8.
Signal is "on" as long as the tool is running
reverse.
"On": short pin 9 - Pin 10.
250 mA maximum.
12 VDC jumper modification :
To connect to pin 11 to output.
N/A
N/A