English
● Be sure that the motor is free
of motion to enable torque
measurement.
The cable shall not apply traction to the
tool.
CONTROL AND SOFTWARE
Power supply by means of CVI3 controller with
the appropriate embedded program version.
MAINTENANCE INSTRUCTIONS
Maintenance should be performed by qualified
personnel only.
● Prior to any maintenance task, disconnect the
tool.
● When disassembling / reassembling the tool,
take the following precautions:
- Check that the controller is switched off.
- Disconnect the cable.
● When disassembling the tool electronics, take
extra care for the wires when pulling out the
connectors.
● When disassembling the tool front assemblies,
take care for the torque transducer wires.
Every 500,000 cycles:
● Check that components are in good condition
and apply grease on mechanical parts when
performing preventive maintenance.
Do not apply too much grease on gears
or bearings; a thin coat shall be sufficient.
ASSEMBLING AND DISASSEMBLING
The use of spare parts other than those
originally supplied by the manufacturer
may result in a drop in performance or
in increased maintenance and level of
vibration and in the full cancellation of the
manufacturer's liability.
● Follow standard engineering practices for the
mounting of component subassemblies.
MEANING OF THE PICTOGRAMS
Left hand thread
When reassembling, apply the
recommended glue
When reassembling, tighten to the
required torque
When reassembling, lubricate with the
required grease or oil.
07/2015
When disposing of components,
lubricants, etc.. ensure that the relevant
safety procedures are carried out.
According to Directive 2002/96/
CE concerning Waste Electrical and
Electronic Equipment (WEEE), this
product must be recycled. Please
contact your "Customer Centre"
or consult the website "www.
desouttertools.com" to find out where
you can recycle this product.
21 / 72
6159920550_03