6159931420_23
WIFI NETWORK CONNECTION
(FOR ELC-W TOOLS)
Q2
See page 15.
SPECIFIC COMMUNICATION LED
(FOR ELC-* TOOLS)
R
See page 16.
No communication to network.
See "Q" page 15.
Tool locked.
Batch complete.
Preventive maintenance.
ELC-W SET UP
T
See page 17.
Legend
1
Plant network
2
Ethernet link
3
Battery nutrunner
Check you have the following equipment:
● ELC-W Battery nutrunner.
- Battery.
- Charger.
- e-DOCK device to connect the tool to the
PC.
● PC with an Open Protocol interface.
● Desoutter WIFI access point.
- Power cord.
● Ethernet network.
● Ethernet cable (not supplied) to connect the
Wi-Fi access point to the PC.
● Standard PC connected to the Ethernet
network and equipped with the Desoutter
Elit Suite software to create and control the
tightening processes.
Before starting
Before starting the set up, check that you have
the following information on hand:
● WIFI access point
Parameters
IP address
Network name (SSID)
Security type
Encryption type
Security key
● ELC-W Battery Nutrunner
● Plant network
Check with your local Desoutter representative
how to set up your specific system environment.
● To get the complete list of the configuration
Wi-Fi access point
● Contact your local Desoutter representative
Battery nutrunner
● Insert the battery pack and plug the e-DOCK
● Connect the e-DOCK to the PC USB port. A
● Launch ELIT CONFIG software and select
● Change the parameters according to your
POWER LEVEL AND PERMITTED
CHANNELS SETUP (ELC-Z)
1. Refer to 6159920990 ElitBox user manual to
2. Follow "Tool paring" procedure in
Now your ELC-Z is fully synchronised with
ElitBox permitted channels and power level.
PREVENTIVE MAINTENANCE
It is recommended to lubricate (use Molykote
BR2+ grease) the clutch and the gearbox every:
By default
192.168.5.201
Desoutter_1
WPA/WPA2PSK
AES/CCMP
mydesoutter_1
20 / 130
Parameters
IP address
Parameters
Communication port
Subnet Mask
by default, refer to the ELIT CONFIG
user manual at http://resource-center.
desouttertools.com.
for more information.
When delivered, all battery nutrunners
are set with the same communication
parameters.
● Change the battery nutrunner IP
address and the communication port
to avoid settings issues.
as shown page 15.
New serial port is created.
"WIFI Tool" tab on the left top of the screen.
installation.
setup ELITBOX,
6159920990 ElitBox user manual
- 500,000 cycles for 18V tools.
- 250,000 cycles for 36V tools.
ELC tools only
● Perform the maintenance of the
clutch every 500,000 cycles.
● Contact your local Desoutter
representative for the maintenance
procedure.
English
By default
192.168.5.221
By default
4545
255.255.0.0
09/2019