1
Safety Guidelines
1.
Follow the installation instructions.
2.
Use the appliance
• according to its intended use
• in good condition
• with due regard to safety and risk of danger.
3.
Note that the appliance is exclusively for use in the
applications detailed in these installation instructions
(see 2 Technical Data). Any other use will not be
considered to comply with requirements and would
invalidate the warranty.
4.
Please take note that any assembly, commissioning,
servicing and adjustment work may only be carried
out by authorized persons.
5.
Immediately rectify any malfunctions which may
influence safety.
2
Technical Data
The diaphragm safety valve is only suitable to drain drinking
water from closed drinking water systems according to
EN 806-5 for protection against exceeding pressure.
Media
Medium:
Connections/Sizes
Internal thread on inlet:
Internal thread on outlet:
Pressure values
Opening pressure:
Operating temperatures
Operating temperature:
Specifications
Installation position:
Valve size:
* Subsequent alteration of the setting is not permitted and is
impossible without destroying the security cap
3
Options
For Options visit homecomfort.resideo.com/europe
4
Assembly
4.1 Installation Guidelines
•
Safety valve must be installed in the cold water supply
pipework before the water heater
•
The installation must be carried out so that:
– There are no shut-off valves or fittings, narrowing
of the pipework or strainers between the water
heater and the safety valve
MU1H-1367GE23 R0420
Drinking water
1
3
/
",
/
"
2
4
1
/
", 3/
", 1"
2
4
6, 8 or 10 bar*
95 °C
Horizontal with safety cap
pointing up
Defined by the size of the
inlet connection
GB
– Good access is provided for service and
maintenance
– The draining water must be visible and mustn't
damage persons or electrical devices
– The safety valve is fitted above the top of the water
heater to avoid the need for draining down when
exchanging the safety valve insert
– That between the safety valve and heat exchanger
a max. 1 m long straight connection line with the
size of the inlet diameter is installed
•
The discharge line must be performed to the size of
the safety valve outlet diameter and may not have
more than 2 elbows and or be longer than 2 m
•
The discharge line must be installed with an incline
•
If there is no drainage facility in the room where the
heater is installed, then the safety valve may be fitted
in an adjacent area. DIN 1988-200 is to be observed
•
The installation location should be protected against
frost
•
The safety valve must be mounted so that in its
installed condition no external forces act on it
•
Nearby the safety valve must be signed
– Drainage water can discharge
– Not locking!
•
Requires regular maintenance in accordance with
EN 806-5
4.2 Assembly instructions
CAUTION!
The safety valve may not be overheated through
welding and soldering work on the system. Install
the safety valve only after these tasks are
completed.
1.
Thoroughly flush pipework
2.
Install the membrane safety valve
• Tighten the connections with max. 18 Nm when
joining. Cracks may form in the material when
tighten to strongly which may cause leaks in the
system.
• Installation in horizontal pipe with safety cap
pointing up
• Note flow direction
• Install without tension or bending stresses
3.
Install discharge line
CAUTION!
Risk of scalding through hot liquid escaping from
the discharge opening.
Route discharge line so that neither personal
injuries nor property damage can be caused by
discharged fluid.
3