Description Of Fault Indications - Grundfos Multilift M Serie Instrucciones De Instalación Y Funcionamiento

Ocultar thumbs Ver también para Multilift M Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 186

6.4 Description of fault indications

If a fault occurs, the symbol
the 14-segment characters in the display. To see the kind of fault, if it is automatically reset and the code is not longer visible, open the
fault log (see fig. 13). When you leave the fault log, the symbol
The last 20 faults are stored in the fault log as fault codes. The meaning of the fault codes are described in the table below:
Fault
Meaning
code
F001
Phase sequence failure
F002
One phase missing
F003
High liquid level
F004
Sensor failure
F005
Overtemperature, pump 1
F006
Overtemperature, pump 2
F007
Overcurrent, pump 1
F008
Overcurrent, pump 2
F009
Undercurrent, pump 1
F010
Undercurrent, pump 2
Operating time exceeded,
F011
pump 1
Operating time exceeded,
F012
pump 2
F013
External fault
F014
Battery failure
Relay or contactor does
F015
not open, pump 1
Relay or contactor does
F016
not close, pump 1
Relay or contactor does
F017
not open, pump 2
Relay or contactor does
F018
not close, pump 2
22
will be visible, an audible alarm will be given by the buzzer and the fault code will be written by means of
Displayed
Flashing
text
symbols
F001
F002
F003
SENSOR
-
TEMP
TEMP
F007
F008
F009
F010
F011
F012
EXT
-
BAT
-
RELAY
RELAY
RELAY
RELAY
will disappear.
How to
reset fault
indications Description
Auto Man
(Only three-phase pumps)
The phase sequence between control board and power
supply is wrong. See fig. 14.
(Only three-phase pumps)
One phase is missing.
The liquid level is high in relation to preset value.
Sensor signal out of range or lost.
Motor thermal switches connected to the controller will
stop pump in case of overheating.
Not relevant for Multilift M.
The pump is stopped if an overcurrent is measured for a
certain period of time (blockage protection).
Not relevant for Multilift M.
The pump is stopped if an undercurrent is measured for a
certain period of time (dry running protection).
Not relevant for Multilift M.
The pump is stopped if normal operating time of the pump
is exceeded, e.g. due to venting problems of pump
housing, closed discharge valve (forgotten to open it after
service/maintenance), forgotten to switch back to
automatic mode, if ON-OFF-AUTO switch is set to "ON"
for service/maintenance. A subsequent emergency
operation starts and stops the pump automatically until
the controller gets a regular stop signal from the sensor.
The controller then switches back to normal operation.
Not relevant for Multilift M.
An external level switch can be connected to the
controller to give an alarm when basement outside the
lifting station is flooded by groundwater or water from
burst water pipe.
The battery is empty and must be replaced.
The pump receives a signal to stop, but does not react.
This situation is detected by current measurement.
The pump receives a signal to start, but does not react.
This situation is detected by current measurement.
Not relevant for Multilift M.
Not relevant for Multilift M.

Publicidad

Tabla de contenido
loading

Tabla de contenido