SETTING ASSESSMENT CRITERIA (AVERAGE MODE) *IN CASE OF SMART FUNCTION ON

NB08PT-18
PB2500Smart
Open "Smart Function" menu from the
setting menu
Not Available
Touch "Assessment".
Turn ON Average mode and Touch "Average
mode"
(Blue: ON, Black: OFF)
Set 5 rivets you use to collect the riveting
data.
Cursor moves rightward every setting
automatically.
If you want/need to get new data, touch the
value of result you want to change and set a
rivet again.
After completing, touch "Criteria" icon to set
the ranges for Stroke and Force.
Set the ranges for Stroke and Force. Touch
Criteria icon
the range value you want to change with
Up-Down icons.
*Default settings: 20% each
Note, if you set the range to too small one, it
has a potential that NOK occurs frequently.
Reference measurement accuracies are as
follows.
Stroke: ±0.5mm
Force: ±500N~1,000N
After setting, touch "Back Home" icon.