Important: disconnect the unit from the main power lines before carrying out any operation inside the unit.

Electrical connections

230V a.c. power input
L1-L2
230V a.c. single-phase motor
U-W-V
230V a.c. output in motion (e.h. flashing light)
W-E
24V a.c. Powering accessories (max. 20W)
0-1
Pushbutton stop (N.C.)
1-2
Pushbutton opens (N.O.)
2-3
Pushbutton closes (N.O.)
2-4
Contact radio and/or button control for "open-close-
2-7
revere
Contact (N.C.) for «re-aperture during closure»
2-C
Automatic closing
NOTE: select the "human presence" funtion (buttons must be held down during operation) by cutting the oint labelled
6
The data and information provided in this manual are to be considered susceptible to change at any time without warning, by CAME cancelli automatici s.p.a.
Key selector
2-3-4
Switch for automatic closure
T1-T2
Connection limit switch opens (N.C.)
0-FA
Connection limit switch closes (N.C.)
0-FC
24V (3W max.) gate-closed signal lamp
1-FA
24V (3W max.) gate-opened signal lamp
1-FC
Contact output (N.O.) with plug-in two-channel
B1-B2
riceiver. Resistive load: 1A 24V d.c.
Antenna connection
.