Electrical connections

L-N
230V (a.c.) power supply 50/60 Hz
10-11 24V (a.c.) max. 30W supply accessories
10-E6 24V Done-shaped filshing light and/or luminous cord
2-C1 Contact (N.C.) of «reopening during closing»
2-C5 Contact (N.O.) of «immediate closing»
U-V-W 230V (a.c.) motor
+ E D Encoder connection
Adjustments
C
A.C.T Trimmer = min. automatic closing time 1 sec, max. 120 sec.
The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
Electrical connection to operate the photocells' safety test
- Set DIP switch 8 to ON to activate the test.
(DIR)
IMPORTANT:
When the safety test function is activated, the N.C. contacts:
- If unused – are to be excluded on their relative DIP switches.
1-2
Stop pushbutton (N.C.)
2-3
Open pushbutton (N.O.)
2-4
Closing pushbutton (N.O.)
2-7
Pulsante per comandi (N.O.)
F-FA
Open end stop connection (N.C.)
F-FC
Close end stop connection (N.C.)
Connection of antenna