Electrical connections

L1-L2 Power supply 230V (a.c.) 50/60 Hz
10-11 Terminals for powering 24V (a.c.) accessories
W-E
Flashing light (socket rating: 230V - 25W max.)
U-V-W Motor single-phase 230V (a.c.) max. 500W
2-C1 Re-open during closing (N.C.) socket
1-2
Stop button (N.C. socket)
Activating the remote control
-Connect the antenna's RG58 cable to the apposite terminals.
-Lock the radiofrequency card into the electronic card
ries).
N.B.: the electronic card only recognises the radiofrequency card when the power is on.
Memorisation
A
-Keep the "PROG"
button on the electronic card pressed. The LED fl ashes.
-Press the transmitter button you wish to memorise. The LED will stay on to show memorisation has been successful.
The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
2-3
Keyswitch and/or open button (N.O.)
2-4
Keyswitch and/or close button (N.O.
F-FA
Opening limit switch (N.C.)
F-FC
Closure limit switch (N.C.)
Connection of antenna