Electrical connections
Power supply 230V (a.c.) 50/60 Hz
L-N
Terminals for powering 24V (a.c.) accessories
10-11
10-E1 Flashing light (socket rating: 24V - 25W max.)
Open gate indicator-light (socket rating: 24V - 3W max.).
10-5
2-CY -"partial stop"/"Stand-by Obstacle" (N.C.) socket
(see Function Selection, page 11)
24V d.c. gearmotor featuring delayed action on
M1-N1-ENC1
opening
24V d.c. gearmotor featuring delayed action on
M2-N2-ENC2
closing
Activating the remote control
-
Connect the antenna's RG58 cable to the apposite terminals.
-Lock the radiofrequency card into the electronic card
N.B.: the electronic card only recognises the radiofrequency card when the power is on.
Memorisation
CH1 = Channel for direct command to a function of the the gearmotor's card,
("open only / "open-close-invert" or "open-stop-close-stop" command,
depending on the choice made on DIP switches 2 and 3).
-Keep the "CH1" button on the electronic card pressed. The LED fl ashes.
-Press the transmitter button you wish to memorise. The LED will stay on to show memorisation has been successful.
-Repeat the points 1 and 2 procedures for the "CH2" button associating this to another button on the transmitter
The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
D
AFTER CUTTING OFF THE POWER SUPPLY (or after disconnecting the batteries).
B C
"Re-open during closing" (N.C.) socket
2-CX
Stop button (N.C. socket)
1-2
Keyswitch and/or opening button (N.O.)
2-3
Keyswitch and/or partial opening button (N.O.)
2-3P
Keyswitch and/or closing button (N.O.)
2-4
Keyswitch and/or commands button (N.O.)
2-7
B1-B2 Possible output of the radio receiver's second channel
(N.O.). Socket rating: 5A-24V (d.c.).
Connection of antenna
CH2 = Channel for direct command an accessory device connected to
B1-B2.
.