■ INSTALLATION
Install the mixer on a hard and horizontal
soil in order to ensure a good stability to
the machine.
Clear the surroundings of the machine
from all thing likely to occasion a risk of
accident or to impede the operator.
Before starting your mixer make
sure that :
◆ Electric driven mixer
• The tension of the network is 230 volts
on two wires.
• Minimum capacity of the meter should
be 5 Amps.
• The motor hood set benefits from double
insulation class II protection grade IP 44.
• Foresee a two wires supply cable having
a section of 2,5 mm2 for a maximum
length of 50 m (equipment class II no
need for a ground wire). If length is more
than 50 m, foresee a cable with a bigger
section.
Safety INSTRUCTIONS
General
Before starting your mixer, check that :
• all protection devices are in position
and good condition.
• Nobody is into contact or close to the
mixer, and no tool is leaning against it.
◆ Electric driven mixer
• Never let a cable rolled on its support,
this will cause impodant drops of tension
and lead to overheating.
• The line must be fitted with fuses or
circuit breaker to ensure the protection.
• Do not plug in and use the electric
motor without making sure that the
motor hood is closed.
GB
■ MAINTENANCE
• After each use, clean the inside and the
outside of your mixer. If you wash it with a
high pressure cleaner, make sure that the
water projections do not reach the motor.
• For a good and efficient leaning of the drum,
use a shovel of gravels and water.
• Do not forget from time to time to grease the
bearing of the bracket, a hole is foreseen for
this.
• The bearings of the drum and of the driving
axle are greased for life.
• The slew ring is made of synthetic material,
high resistance, unalterable, maintenance
and greasing free,
efficiently to the reduction of sound
nuisances.
which participates