Status Led; Troubleshooting - geberit 116.076.00.1 Operación Manual

Ocultar thumbs Ver también para 116.076.00.1:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 38
EN

Status LED

The status LED on the urinal flush control shows the following statuses:
Status
Off
Lights up green
Flashes red
Lights up red
1)
The state of battery charge can be checked using a Geberit app.

Troubleshooting

Malfunction
No flush actuation
Incorrect flushes (too
soon, too late, unwanted)
Flushing out of the urinal
ceramic is inadequate.
Water is splashing out
from the urinal ceramic.
Residual water in urinal
ceramic appliance is not
draining
1)
The state of battery charge can be checked using a Geberit app.
14
Status
• No mains voltage or batteries flat
• OK
• Low state of battery charge
• Very low state of battery charge
• Solenoid valve defective
• Sensor defective or not connected
Cause
Mains operation:
Network failure (green LED on
power supply unit does not light up)
Battery operation:
1)
Batteries flat
Water supply valve closed
Technical fault
Unsatisfactory user recognition due
to urine scale deposits in the urinal
trap
Technical fault
Flush time set incorrectly
Screen filter in solenoid valve
clogged
Water pressure too low
Flow rate too high
Urinal trap or discharge pipe
clogged
1)
1)
1)
Action
▶ Check the power
supply.
▶ Replace the batteries.
→ See "Replace the
batteries", page 15.
▶ Open the water supply
valve.
▶ Contact a skilled
person.
▶ Clean the urinal trap.
→ See "Cleaning the
urinal trap", page 15.
▶ Contact a skilled
person.
▶ Set flush time. → See
"Setting the flush time",
page 15.
▶ Contact a skilled
person.
▶ Contact a skilled
person.
▶ Contact a skilled
person.
▶ Contact a skilled
person.
9007206862832523-1 © 04-2021
970.151.00.0(00)

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

116.077.00.1

Tabla de contenido