4
CONFIGURATION
4.2

WT teach modes

5

Troubleshooting

5.1
Troubleshooting
10
Teach-in mode
Teach-in time /
for objects /
Teach-in time
Teach-in mode
for objects
Single teach-in
Approx. 1.0 s
pushbutton
ET: Connect pin 5
> 2s
or gray wire to UV
for > 2 to < 4 s ().
The Troubleshooting table indicates measures to be taken if the sensor stops working.
Table 1: Störungsbehebung
LED indicator/fault pattern
Green LED does not light up
Green LED lights up, no output
signal when object is detected
Green LED flashes
Switching outputs not accord‐
ing to graphic C
Yellow LEDs flash at the same
time
Yellow LED flashes (only briefly) Teach-in mode
Yellow LED lights up, no object
in the path of the beam
Object is in the path of the
beam, yellow LED does not
light up
Alignment /
LED indicator /
Alignment
LED indicator
Sensor to object
Ö
Sensor to object
Ö
Cause
No voltage or voltage below
the limit values
Voltage interruptions
Sensor is faulty
Test input (Test) is not con‐
nected properly
IO-Link communication
IO-Link communication
Parameter settings made
manually, which deviate from
the standard
The sensor is not ready for
operation. The sensor will be
in the warming-up phase at
low ambient temperatures.
The sensor will have shut
down at excessively high
ambient temperatures.
Distance between the sensor
and the background is too
short
Distance between the sensor
and the object is too long or
sensing range is set too short
Results /
Results
Sensing range is
adjusted accord‐
ing to object
Sensing range is
adjusted accord‐
ing to object
Measures
Check the power supply,
check all electrical connec‐
tions (cables and plug connec‐
tions)
Ensure there is a stable power
supply without interruptions
If the power supply is OK,
replace the sensor
See the note on connecting
the TI
-
-
Initiate a factory reset. The
switching outputs are reset to
factory settings.
At low ambient temperatures,
wait until the sensor has
warmed up. Ensure the sensor
cools down at excessively high
ambient temperatures.
Check the teach-in mode
Reduce the sensing range,
see graphic F
Increase the sensing range,
see graphic F
8018110.1BVZ / 2021-05-18 | SICK