ENGLISH
Never direct the laser beam to people or animals and never leave this device running unattended.
This laser may only be used for shows. The operation of a class 3B show laser is only allowed if the
operation is controlled by a skilled and well-trained operator.
Depending on the classification, operating a laser product can produce laser radiation that may cause
permanent eye damage and/or skin damage. The legal instructions for using a laser product vary from
country to country. The user must always inform himself on the legal instructions valid in his country and
apply them to his situation.
Please note that JB SYSTEMS cannot be made liable for damages caused by incorrect installations and
unskilled operation!
DESCRIPTION:
1. MAINS INPUT: with IEC socket and integrated fuse holder, connect the supplied mains cable here.
2. ON/OFF KEY ACTUATED SWITCH: used to switch the unit on/off. Use the keys to make sure only a
skilled operator is able to switch the laser on.
3. INTERNAL MICROPHONE: The built-in microphone is used to synchronize the laser show to the beat of
the music.
4. DMX INPUT: 3pin male XLR-connector used to connect universal DMX-cables. This input receives
instructions from a DMX-controller.
5. DMX OUTPUT: 3pin female XLR-connector used to connect the LASER BURST with the next unit in the
DMX chain.
6. DISPLAY: shows the selected DMX address when the unit is in DMX-mode. Shows 3 horizontal lines
when the unit is in stand-alone mode.
7. DIP-SWITCHES: switches 1~8 are used to set the DMX address between 000 and 255. Switch 9 is not
used and switch 10 is used to select stand-alone or DMX mode.
8. PROGRAM SWITCH: when the unit is used in stand-alone mode, you can use this switch to choose
from 4 different working modes:
1. DISCO MODE: patterns move quickly to the rhythm of the beat.
2. BAR MODE: the same as DISCO mode but the patterns move slower to the rhythm of the beat
3. RANDOM MODE: a random mix of the DISCO and BAR modes.
4. AUTO MODE: patterns move automatically, without music activation.
9. SAFETY EYE: used to attach a safety cable when the unit is rigged (see paragraph "overhead rigging"
10. MUSIC INPUT SENSITIVITY: This potentiometer is used to adjust the music input sensitivity. Turn the
potentiometer until the laser works in sync with the music.
11. COOLING FAN: used to cool the components inside the enclosure.
Make sure to never cover this fan outlet!
12. INTERLOCK input: used to connect the optional emergency stop
switch (see picture). When you push this switch the laser beam will
disappear immediately.
IMPORTANT! For your own safety we strongly recommend to
connect this optional switch!
JB SYSTEMS
®
USER MANUAL
3/41
LASER BURST
ENGLISH
13. POWER LED: indicates that the unit is switched on.
14. SOUND LED: flashes to the sound of the music detected by the internal microphone.
15. HANGING BRACKET: with 2 knobs on both sides to fasten the unit and a mounting hole to fix a
mounting hook.
16. LASER OUTPUT: Here the laser beam leaves the enclosure, make sure to NEVER look inside the unit
through this opening while the laser effect is switched on!
17. WARNING LABEL: "Caution – Class 3B laser. Laser Radiation when open. Avoid exposure to beam."
18. WARNING LABEL: "Laser Aperture"
19. LASER WARNING SIGN: warns against a potentially dangerous laser when not used by skilled
operators.
20. WARNING LABEL: "Laser Radiation. Avoid exposure to beam. Class 3B laser product"
OVERHEAD RIGGING
Important: The installation must be carried out by qualified service personal only. Improper
installation can result in serious injuries and/or damage to property. Overhead rigging requires
extensive experience! Working load limits should be respected, certified installation materials
should be used, the installed device should be inspected regularly for safety.
Make sure the area below the installation place is free from unwanted persons during rigging, de-rigging
and servicing.
Locate the fixture in a well ventilated spot, far away from any flammable materials and/or liquids. The
fixture must be fixed at least 50cm from surrounding walls.
The device should be installed out of reach of people and outside areas where persons may walk by or be
seated.
Before rigging make sure that the installation area can hold a minimum point load of 10times the device's
weight.
Always use a certified safety cable that can hold 12times the weight of the device when installing the unit.
This secondary safety attachment should be installed in a way that no part of the installation can drop
more than 20cm if the main attachment fails.
The device should be well fixed; a free-swinging mounting is dangerous and may not be considered!
Don't cover any ventilation openings as this may result in overheating.
The operator has to make sure that the safety-relating and machine-technical installations are approved by
an expert before using them for the first time. The installations should be inspected every year by a skilled
person to be sure that safety is still optimal.
CAUTION EYEDAMAGE: Always position the laser in a way that prevents the
audience from looking directly into the laser beams. The installation should assure that
the beam will not strike the audience.
JB SYSTEMS
®