8.6 Terminal Allocation for Analog Interface X20
Item
Function of Analog Interface X20 Connection for
1
Analog output 0
2
n.c.
3
Analog GND
4
n.c.
5
n.c.
6
Analog GND
7
n.c.
8
Analog input 0
9 -15
n.c.
Connecting analog signals
© Festo Didactic 8090920
Description
Motor Controller
17
Analogue monitor output 0, +10 V ±10 %
5
n.c.
14
Analog GND
14
Analog GND
(2)
can be connected with AIN0 via a selector
switch.
39