Maintenance
3.2 PRODUCT SPECIFICATIONS
3.2.1 GENERATOR SPECIFICATIONS
Rated. Power ..............................................................5.0/5.5/6.5 kW**
Surge Power ...............................................................6.25/6.88/8.0 kW
Rated AC Voltage ......................................................................120/240
Rated AC Load
Current @ 240V (5.0/5.5/6.5 kW) ..................20.8/22.9/27.1 Amps**
Current @ 120V (5.0/5.5/6.5 kW) ..................41.7/45.8/54.2 Amps**
Rated Frequency .................................................... 60 Hz @ 3600 RPM
Phase ................................................................................ Single Phase
** Maximum wattage and current are subject to, and limited by, such factors
as fuel Btu content, ambient temperature, altitude, engine condition, etc..
Maximum power decreases about 3.5% for each 1,000 feet above sea level;
and will also decrease about 1% for each 6° C (10° F) above 16° C (60° F)
ambient temperature.
3.2.2 ENGINE SPECIFICATIONS
Displacement .............................................................................. 389 cc
Spark Plug Type ................................ NHSP F7RTC or Champion RN9YC
Spark Plug Gap (5.0/6.5 kW) ........0.028-0.031 inch or (0.70-0.80 mm)
Gasoline Capacity ......................................................... 6.6 U.S. gallons
Oil Type.................. See Chart in "Before Starting the Generator" Section
Oil Capacity ................................................................. 1.1 L (1.16 Qts.)
Class II Emission Certified*
* The engine manufacturer must warrant the emission control system
for a period of two years. This warranty coverage is in addition to
the warranty provided by Generac, and may cover the engine even if
Generac's warranty does not.
3.3 GENERAL RECOMMENDATIONS
The warranty of the generator does not cover items that have been
subjected to operator abuse or negligence. To receive full value
from the warranty, the operator must maintain the generator as
instructed in this manual.
Some adjustments will need to be made periodically to properly
maintain the generator.
All adjustments in the Maintenance section of this manual should
be made at least once each season. Follow the requirements in the
"Maintenance Schedule".
Once a year replace the spark plug and replace the air filter.
A new spark plug and clean air filter assure proper fuel-air
mixture and help the engine run better and last longer.
3.3.1 GENERATOR MAINTENANCE
Generator maintenance consists of keeping the unit clean and dry.
Operate and store the unit in a clean dry environment where it will
not be exposed to excessive dust, dirt, moisture or any corrosive
vapors. Cooling air slots in the generator must not become clogged
with snow, leaves, or any other foreign material.
10
NOTE:
Check the cleanliness of the generator frequently and clean when
dust, dirt, oil, moisture or other foreign substances are visible on
its exterior surface.
Never insert any object or tool through the air cooling
slots, even if the engine is not running.
DO NOT use a garden hose to clean generator. Water can enter
the engine fuel system and cause problems. In addition, if water
enters the generator through cooling air slots, some water will
be retained in voids and crevices of the rotor and stator winding
insulation. Water and dirt buildup on the generator internal
windings will eventually decrease the insulation resistance of
these windings.
3.3.2 TO CLEAN THE GENERATOR
• Use a damp cloth to wipe exterior surfaces clean.
• A soft, bristle brush may be used to loosen caked on dirt, oil,
etc.
• A vacuum cleaner may be used to pick up loose dirt and debris.
• Low pressure air (not to exceed 25 psi) may be used to
blow away dirt. Inspect cooling air slots and openings
on the generator. These openings must be kept clean and
unobstructed.
3.3.3 ENGINE MAINTENANCE
When working on the generator, always disconnect
negative cable from battery. Also disconnect spark plug
wires from spark plug and keep wire away from spark
plug.
3.3.4 CHECKING OIL LEVEL
See the "Before Starting the Generator" section for information on
checking the oil level. The oil level should be checked before each
use, or at least every eight hours of operation. Keep the oil level
maintained.
3.3.5 CHANGING THE OIL
Change the oil every 100 hours. If running this unit under dirty or
dusty conditions, or in extremely hot weather, change the oil more
often.
Hot oil may cause burns. Allow engine to cool before
draining oil. Avoid prolonged or repeated skin exposure
with used oil. Thoroughly wash exposed areas with soap.
NOTE: