6
INSTALL THE CASE
IN THE WINDOW
Adjust the leveling bolts and nuts against the
D
outside wall so that the case has a slight tilt
to the outside. Tighten nuts with an adjustable
wrench. Use a level; about a 1/2 bubble will
be the correct case slant to the outside.
Use a wood block (obtained locally) between
E
the leveling bolts and the wall if the wall is
weak or if the weight of the air conditioner
falls between the studs in the wall.
Extend the left and right accordion panels
F
to the vertical window sashes. Drill pilot
holes and attach the top and bottom corners
with 4 type D screws.
Top mounting rail
Type D
screw
Type D
screw
Installation Instructions
(cont.)
Type D
screw
Type D
screw
7
INSTALL SUPPORT BRACKETS
AND THE FOAM TOP WINDOW
GASKET
Attach the support brackets with two
A
type E screws, one on each side.
Cut the foam top window gasket to the
B
window width.
Stuff the foam between the glass and the
C
window to prevent air and insects from
getting into the room.
11