1°) INSTALLATION
See General Warnings 1 to 6
(see fig. 4)
Installation of vertical wall mounted water-heater: To enable the heating element to be replaced, leave free space below the ends of the pipes of the
appliance.
2°) COMBINED WATER HEATER CONNECTION
See General Warnings 10 to 14
(see. fig. 1 and 2)
All water supply pipes must be thoroughly cleaned before connection. The connection of the hot water outlet must be made using a cast iron or steel sleeve
of a dielectric union in order to avoid corrosion of the tubes (due to direct contact between iron and copper). A brass union must not be used.
Secondary Circuit (Unvented installation) (see. fig 2): A new safety device complied with the current standards (in Europe EN 1487) must be fitted with a
rated pressure of 9 bar (0,9 Mpa), and dimension 1/2 ''. The safety valve must be protected from frost. No water accessory must be installed between the
safety device and the cold water inlet to the appliance. A pressure reducing valve (not supplied) is recommended when water supply pressure exceeds 5 bar
(0,5 MPa) . Connect the safety device to an unpressurised outlet pipe in a frost free environment, with a continuous slope for the evacuation of the water
during heating up or draining the water heater. Pipes used must be capable of withstanding a temperature of 100 °C and a pressure of 10 bar (1 MPa).
Attention: Do not use the safety valve included in this packaging in France (Métropole and DOM-TOM...)
Primary circuit (heating) (see. fig 1):: Protect from excessive pressure due to expansion of water during heating with a 3 bar (0,3 MPa) valve or a header
tank of the open (to atmospheric pressure) type or a closed type diaphragm tank. The circuit working pressure must not exceed 3 bar (0,3 MPa); its
temperature must not exceed 100°C.)
Working principle with booster pump: Plan a sensor, it will pilot the pump of the boiler.
Connection in series: When several appliances are connected in series, ensure that the safety device is capable of accepting high temperatures
.
3°) ELECTRIC CONNECTION (fig. A)
The water heater can be connected and powered only by a single-phase 230V~ AC mains supply. Connect the water heater via a fixed duct with a cross
section of 2.5 mm2. For that, use standard channelling (fixed or fluted conduit) to the calibrated receptacle in the cover. For appliances supplied with a cable
or a plug (prohibited in France), connect up directly. The earthing conductor must be connected to earth or lead the earth wire to the terminal provided
indicated by the symbol
. This connection is absolutely necessary for safety reasons. The green/yellow earth lead must be longer than the two live
wires. Installation must include upstream of the appliance, an all pole cut-out device (contact opening at least 3 mm: fuse, breaker switch). When the water
pipes are made of insulating material, the electrical contacts must be protected by a 30 mA earth-leakage breaker conforming to the standards in force.
Thermal circuit breaker: All our products are equipped with a thermostat with thermal circuit breaker and manual resetting which cuts off the power supply
to the water heater in case of overheating. Warning: If the safety trips a) switch off the power before taking any further action, b) remove the cover, c)
check the electrical connections, d) reset the thermal circuit breaker. If the circuit breaker keeps tripping, replace the thermostat. Never short
circuit the safety cut out or the thermostat. Connect the power supply only via the terminal.
ELECTRICAL CONNECTION. - Optional kits: For the installation and electrical connection of the kits refer to the instruction included with each package.
When using a tank for a solar system takes not of local legislation. (E.g.: prohibited in Spain)
4°) SETUP &OPERATION
WARNING: Never switch on the water heater without water.
The secondary circuit must be filled, before switching on, open the hot water taps, vent the pipes of air and fill the appliance.
Fill the primary circuit (circuit connected to the boiler) Open the water tap, unscrew the air vent to purge air introduced by the filing operation. For an
installation fitted with a booster pump, switch it on for a moment or two to speed up de-gassing. Check that the system is full of water, either by checking the
level of water in the open header tank, or by opening the vent at the top of the installation.