GENERAL WARNINGS

This unit can be used by children of not less than 8 years and people with reduced physical, sensory or mental capabilities or without experience or
knowledge if they are properly supervised or if the instructions for using the device safely have been given and if the risks are taking into account.
Children must not play with the device. Cleaning and maintenance must not be done by children without supervision
Important: Installation of the water heater must comply with national standards in the country of installation. If you are not sure that your knowledge is
sufficient to install this product, we advise you to consult a professional.
Warning: Heavy items, to be handled with care
1/ Install the device in premises free from frost. Destruction of the device by overpressure due to blockage of the safety unit is outside the guarantee.
2/ Make sure that the wall is capable of supporting the weight of the device when full of water.
3/ If the device is to be installed in premises or a location whose ambient temperature is permanently above 35°C, provide ventilation of the premises
4/ In a bathroom do not install this product in volumes V0, V1 and V2 (see fig. 3). If the water-heater is installed above habitable premises provide a
storage tank with outflow to the drains.
5/ Fit the device in an accessible place. If using PER pipes, we strongly recommend that a thermostatic regulator be fitted to the combined water
heater outlet. It will be set according to the performances of the equipment used.
6/ Vertical wall fixing of the combined water heater: To allow the potential exchange of the heating element, let a free space above the vertical water
heater (minimum 300 mm)
7/ Before removing the cover, ensure that power is disconnected to avoid any risk of injury or electrocution.
8/ The electrical installation must include upstream of the device a pole cut out (circuit breaker or fuse) in accordance with local installation rules. (A 30
mA earth-leakage breaker)
9/ If the cable is damaged, it must be replaced by a special cord or assembly available from the manufacturer or the after sales department.
10/ It is mandatory to install a safety device (9 bar (0,9 MPa), and dimension ½") in a frost safety area (or other new pressure relief device) on the
input of the water heater, which will meet the local standards.
11/ The drain of the pressure relief device must be operated periodically to remove scale deposits and verify that it isn't blocked.
12/ No hydraulic accessory shall be located between the safety device and the cold water inlet. A pressure reducer (not included) is necessary on the
main supply when the pressure is greater than 5 bars (0,5 MPa).
13/ Connect the safety device to a drain pipe, in open air, in a frost-free area and with a continuous slope down in order to drain the water in case of
drain of the combined water heater.
14/ For the connection of secondary circuit use pipes with minimum characteristics pressure 10 bar (1 MPa) and the temperature should not exceed
100 °C.
15/ The operating pressure of primary circuit should not exceed 3 bar (0,3 MPa), the temperature should not exceed 100 °C.
16/ Draining: Disconnect the power supply and cold water inlet, open the hot water taps and operate the drain valve of the safety device.
17/ The products described in this instruction book can change at any time to be in accordance to the new technology and the standards.
Products in accordance with electromagnetic directive 2004/108/EC and Low Voltage directive 2006/95/EC.
18/ Do not throw to the garbage your device but hand it in a collection place where it can be recycled