Loosen the four screws (A) and remove the cover from the transformer seat.
Drill the cable outlet (B) situated in the gear motor base and thread the three-pole power supply cable through, stripping the phase and neutral for approxi-
mately 30 cm and the earth for approximately 5 cm. Fix the cable sheath by tightening the tear-proof clamp (C).
Phase and neutral must be connected to the fuse carrier situated inside the transformer housing (please refer to the control panel instructions), earth
must be crimped to the eyelet (D) screwed onto the base of the gear motor.
Please refer to the detail in fig. 12.2 for the cable passage.
Reposition the cover onto the transformer seat and tighten all screws.
A
B
D
Once the electrical connections have been made, block the gear motor again and reposition the gear motor cover following the procedure illustrated in
paragraph "4 - Preliminary procedures" in the reverse order.
10 - Electrical connections to the control panel
Below are the electrical connections to the control panel if replacement is necessary.
Reposition the cover onto the transformer seat and tighten all screws.