Amprobe PM55A Manual De Uso página 15

Ocultar thumbs Ver también para PM55A:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Capacitance
100.0nF, 1000nF, 10.00µF, 100.0µF
1)
Accuracy below 50nF is not specified
2)
Accuracies with film capacitor or better
3)
Updates > 1 minute on large values
4)
Specified with battery voltage above 2.8 V (half full battery). Accuracy decreases gradually to
12% at low battery warning voltage of approx. 2.4 V.
Resistance
600.0 Ω
6.000 kΩ
60.00 KΩ, 600.0 KΩ
6.000 MΩ
Open Circuit Voltage: 0.4VDC typical
1)AutoTect is for 6.000kΩ ~ 6.000MΩ ranges;
2)Add 40 dgt to specified accuracy while reading is below 20% of range
Frequency
1
Range
10.00 Hz -30.00 kHz
10.00 Hz -999.9 Hz
1
Sensitivity (Sine-rms):
Hz in Auto-VΩ position:> 3 V
2
Line-level Hz in V position
@ 6.000 V ac range:
@ 60.00 V ac range:
@ 600.0 V ac range:
1
Range
3)
1
Range
Accuracy
2
> 3 V
> 6 V
> 60 V
±(0.5%+4 dgt)
13
2
Accuracy
±(3.5%+6 dgt)
4
2
Accuracy
±(2.0%+6 dgt)
±(1.2%+6 dgt)
±(1.0%+4 dgt)
±(2.0%+4 dgt)
Specified At
< 2 0 V Sine-rms
< 600 V Sine-rms

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido