English
Pump is leaky
Three drops per minute are allowable and
can appear on the underside of the unit.
Seek the help of Customer Service if leaks
are more serious.
Pump makes a knocking noise
Check all supply lines as well as the deter-
gent system for leaks.
Evacuate air from the cleaner (see Switch-
ing on the unit).
Clean the fine filter.
Seek the help of Customer Service if nec-
essary.
Detergent is not being drawn in
Set nozzle to "Chem".
Check detergent suction hose with filter for
leaks or obstructions and clean it if neces-
sary.
Clean/renew non-return valve in detergent
suction-hose connection.
Open detergent metering valve or check it
for leaks/remove obstruction. Also clean
the venting orifice in the housing.
Seek the help of Customer Service if nec-
essary.
Operating Instructions HD 10/25 S VEX

Spare parts

You will find a list of spare parts at the end of
these operating instructions.
Warranty
The warranty terms issued by our authorised
marketing company are valid in every country.
We remedy any fault in the unit free of charge
within the warranty period providing the cause
of the fault proves to be a material or manu-
facturing error.
Should you wish to call upon the guarantee,
please apply to your dealer or nearest author-
ised Customer Service centre taking along
also the accessories and bill of sale.