Care And Maintenance; Safety Inspection/Maintenance Contract - Kärcher HD 10/25 S VEX Manual Del Usuario

Ocultar thumbs Ver también para HD 10/25 S VEX:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 13
English
Storing the cleaner
Place the handgun in the support.
Reel in the high-pressure hose and hang it
over the hose rest.
or
Coil the connecting cable round the cable/
hose rest.
Frost protection
Caution!
Frost will destroy a unit that is not com-
pletely empty of water! Store the unit where it
will be free of frost.
If storage away from frost is not possible:
Empty the detergent tank (see care and
maintenance/As and when required).
Drain off the water and rinse the unit
through with anti-freeze.
Leave the unit to dry for max. 1 minute.
Use the standard glycol-based anti-freezes
for cars.
Follow the handling instructions of the anti-
freeze manufacturer.

Care and maintenance

Danger!
!
Before any care and maintenance work
on the unit draw out the mains plug.
Caution!
When changing the oil, dispose of any
waste oil only at authorised collection points.
Safety inspection/Maintenance
contract
You can arrange with your dealer to have a
regular safety inspection carried out or to
have a maintenance contract. Please seek
advice.
Operating Instructions HD 10/25 S VEX
Before each use
Check connecting cable for damage (risk of
getting an electric shock), have a damaged
connecting cable replaced without delay by
authorised Customer Service personnel or
an electrician.
Check high-pressure hose for damage
(danger of explosion), replace a damaged
high-pressure hose without delay.
Check unit (pump) for any leaks.
Three drops per minute are allowable and
can appear on the underside of the unit.
Seek the help of Customer Service if leaks
are more serious.
Every week
Check oil level in oil reservoir: if the oil is
milky (water in oil), seek the help of Cus-
tomer Service immediately.
Clean the fine filter.
– Unpressurize unit.
– Unscrew the fastening screw of the hood
and remove the hood.
– Unscrew the cover with filter.
– Clean the filter with clean water or com-
pressed air.
– Reassemble in the reverse order.
Clean the filter at the suction hose for de-
tergent.
Annually or after 500 operating
hours
Change the oil
– For oil quantity and type see Technical
Specifications.
– Undo the fastening screw, remove the
hood, unscrew the front oil drain plug on
the motor housing.
– Drain oil into a suitable container.
– Screw in the oil drain plug.
– Fill slowly with fresh oil; air bubbles have
to escape.
9

Publicidad

Tabla de contenido
loading

Tabla de contenido