14. Site of installation
An even standing surface with a sufficient load capacity is
essential for setting up the machine in a proper and safe
manner. Any unevenness in the standing surface must be
evened out by metal shims to ensure that the machine is not
standing in a distorted manner.
The BlueMax Mini Modular Plus comes in secure shipment
packaging for safe transportation. A number of components
must be installed to make the machine ready for operation.
After installing the machine, it must be cleaned.
Using the 4 black brackets
conjunction with sliding block on the foot profile), secure
the machine on a bench / base frame to be provided at the
site of installation so as to prevent the machine from falling.
1
CAUTION
Risk of crushing!
Allow a space of at least 500 mm between moving
machine parts and pillars, parts of the building, cabinets
etc.!
Do not stand any laden pallets in this safety zone!
15. Safety guards to be provided by the owner
Safety guards provided by the owner must be easily
accessible and in full working order after installing the
machine. They must not interfere with the machine's own
safety guards in operation on site.
The site of installation must be selected in such a way
that will also allow repairs to be performed at a later date
without physical obstruction.
16. Permissible ambient conditions
• The machine must only be installed and operated in dry
rooms.
• The machine is not explosion-protected. The machine must
not be installed near painting facilities.
• Provide a supply of fresh air to the fan cowls on electric
motors.
• Avoid any external mechanical strain on the machine.
supplied with the machine (in
1
17. Removing preservatives
The machine is only coated with preservatives for
transportation.
• Clean dust and shipping dirt from the machine with a dry
cloth.
• Never use cold-cleaning products, nitrocellulose thinner or
other aggressive chemicals!
• Remove all transport braces. These should be kept for later
re-use.
18. Electrics
The automatic drilling and insertion machine is fitted with
a connection cable and a 16 amp plug. The power socket
must be checked for proper working order by a qualified
electrician.
You will find the applicable connection specifications on the
rating plate on the machine.
Requirements on the electrical power supply
Connection must only be made to an electrical system
complying with VDE 0100. The electrical safety of this
equipment is only guaranteed if it is connected to a
protective earth conductor system that complies with
regulations. It is very important to check that this basic
safety requirement is met and that the machine is provided
with adequate fuse protection. The manufacturer cannot
be held responsible for damage caused by a lacking or
interrupted protective earth conductor. The rating plate
provides information on rated input and the appropriate
fuse protection.
19. Pneumatic connection
The automatic drilling and insertion machine has a fitted
coupler plug, nominal width 7.2
• Max. input pressure 8 bar / 100 PSI
20. Suction extractor
It is compulsory to use a flexible, fire retardant hose for
connection to an extractor system. A suction extraction line
is not included.
• Outside diameter (suction connector)
• Air flow rate
NOTE
For further technical specifications, refer to the
documentation provided by the manufacturers.
Unauthorised changes and modifications to the
system are not permitted for safety reasons and rule
out any liability on the part of the manufacturer for
any resultant damage.
en
80 mm
min. 20 m/s
109