Connecting to compressed air supply
To connect the machine to the compressed air supply system,
push the air supply line onto the air filter using quick release
connector
.
1
Recommended air pressure 6 - 7 bar, 100 psi.
1
Fig. 22: Air filter unit with quick release connector
max. 16A
Mains power fuse
protection to be provided by
customer
BlueMax Mini Modular Plus
3-phase
Vertical drilling unit motor
Fig. 23: Circuit diagram
CE: 1 and 2: grey; 3 and 4: brown;
5 and 6: black; PE: green/yellow
UL/CSA: 1 and 2: red; 3 and 4:
brown;
5 and 6: black; PE: orange
with green/yellow
P = see order
U = see order
I = see order
n = 2800 rpm
Connecting to the power supply
Connect to the power supply using a 16-ampere plug.
Before you do, have a qualified electrician ensure that the
socket is in proper working order.
Now connect the plug to the socket.
The machine is rated for a supply voltage of 400 volts. (other
options are possible)
Use an appropriate plug compliant with the DIN VDE or IEC
standard. An upstream fuse must be provided in the mains
power supply system.
Check motor turning direction. The drive spindles must turn
clockwise.
If the motor or spindles turns anticlockwise, you must reverse
the phases in the plug.
DANGER
Danger from electric shock!
Working on live components in the improper manner
presents a danger to life!
Work on electrical equipment must only be carried out
by authorised electricians!
P = see order
U = see order
I = see order
n = 2800 rpm
Laser set
is optional
Horizontal drilling unit motor
Laser
CE:
1 and 2: grey; 3 and 4: brown;
5 and 6: black; PE: green/yellow
UL/CSA:
1 and 2: red; 3 and 4: brown;
5 and 6: black;
PE: orange with green/yellow
is optional
123
123
en