Specifications; Generator; Engine - Generac G0062700 Manual Del Propietário

Generadores enfriados por aire de 50 hz 8/10/13kva
Ocultar thumbs Ver también para G0062700:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

General Information

Specifications

Generator

Model
Rated Voltage
Rated Maximum Load
Current (Amps) at
Rated Voltage*
Main Circuit Breaker
Phase
Rated AC Frequency
Battery Requirement
Enclosure
Weight (lbs./ kilos)
Normal Operating
Range
These generators are rated in accordance with UL 2200, Safety Standard for Stationary Engine Generator Assemblies, and CSA-C22.2 No. 100-04
Standard for Motors and Generators.
* Natural Gas ratings will depend on specific fuel BTU / joules content. Typical derates are between 10-20% off the LP gas rating.
** Circuits to be moved must be protected by same size breaker. For example, a 15 amp circuit in the main panel must be a 15 amp circuit in the
transfer switch.

Engine

Model
Type of Engine
Number of Cylinders
Displacement
Cylinder Block
Recommended Spark Plug
Spark Plug Gap
Valve Clearance
Starter
Oil Capacity Including Filter
Recommended Oil Filter
Recommended Air Filter
Engine power is subject to and limited by such factors as fuel BTU/joules, ambient temperature and altitude. Engine power decreases about 3.5 percent
for each 1000 feet (304.8 meters) above sea level, and also will decrease about 1 percent for each 10 °F (1 ºC) above 60 °F (15 ºC) ambient temperature.
The specification sheet for your generator was included in the documentation provided with the unit at the time of purchase. For additional copies,
consult your local Independent Authorized Service Dealer for your specific generator model.
6
8 kVA
36.4 / 34.8 / 33.3
40 Amp
Group 26R, 12 Volts and 540 CCA Minimum
Steel
387 / 175.4
This unit is tested in accordance to UL 2200 standards with an operating temperature of -20 ºF (-29 ºC) to 122 ºF
(50 ºC). For areas where temperatures fall below 32 ºF (0 ºC) a cold weather kit is recommended. When operated
above 77 ºF (25 ºC) there may be a decrease in engine power. (Please reference the engine specifications section.
32.3 in
0.030 in (0.76 mm)
0.002–0.004 in (0.05–0.1 mm)
Approx. 1.7 qt (1.6 L)
10 kVA
220/230/240
45.5 / 43.5 / 41.7
50 Amp
1
50 Hz
(See
Replacement
Parts)
Steel
435 / 197.3
8 kVA
GTH-530
2
3
(530 cc)
Aluminum w/ cast iron sleeve
(See
Replacement
12 VDC
(See
Replacement
(See
Replacement
Owner's Manual for 50 Hz Air-Cooled Generators
13 kVA
59.1 / 56.5 / 54.2
63 Amp
Steel
471 / 213.6
10 & 13 kVA
GT-990
2
3
60.5 in
(992 cc)
Parts)
0.040 in (1.02 mm)
0.002–0.004 in (0.05–0.1 mm)
Approx. 1.9 qt (1.8 L)
Parts)
Parts)

Publicidad

Tabla de contenido
loading