INSTALLATION INSTRUCTIONS CONTINUED

Locating the Heater

The heater should be installed out of traffic areas
and at least 6' off the floor. The direction of
airflow should not be restricted (i.e. by columns or
machinery) and the airflow should not be directed
at exposed walls. When more than one heater is
used in an area, the heaters should be arranged
so that the airflow of each heater supports the
airflow of the others to provide best circulation of
warm air as shown below (See Figure 1.2).
NEVER suspend any object
WARNING
from a mounted heater!

Wall/Ceiling Mounting

See Assembly Figure 3
1. Line up holes on bracket with holes on the
heater handle.
2. Attach heater to bracket with 20 mm screw,
lock washer, 10 mm washer, and 10 mm nut in
the larger holes.
The heater must be properly installed before use.
WARNING
Wall mounting
Min. 1/2" (38mm)
HEATER
Min. 72" (1.8 M)
Floor
© 2021, Pinnacle Climate Technologies,Inc
NEVER LEAVE HEATER UNATTENDED WHILE
CONNECTED TO A POWER SOURCE
Figure 1.2
Ceiling
3. Also use 10 mm screw and 5 mm nut to
secure bracket to handle in smaller holes.
4. Locate wood stud in wall or joist in ceiling to
mount heater.
NOTE: Wall stud must be able to support
12 lbs. continuously.
5. Use holes in bracket to mark 2 holes for
drilling.
6. Pre-drill 2 holes for 65 mm screws.
7. Secure two 65 mm screws and washers to
wall/ceiling joist leaving 1/8" exposed. Two (2)
screws must be attached securely to a wood
stud (min. 1.5")
8. Attach bracket to exposed screw head by
sliding through keyholes on bracket and
pushing down to lock the bracket into place.
9. Tighten screws against bracket to secure.
10. Secure one 65 mm screw and washer to
bracket that is against the wall or ceiling stud
(see assembly instructions page 7).
Ceiling Mounted
Min. 1/2" (38mm)
Ceiling
HEATER
Min. 72" (1.8 M)
Floor
Ceiling Mounted Electric Heater User's Manual
6
Ceiling Mounted with 30° Tilt
Min. 6" (153mm)
Min. 72" (1.8 M)
Floor
Ceiling