2.3.7. "Back release" function for cassette awnings only
This function is used for releasing the fabric tension after closing the cassette awning.
The procedure to follow to activate or deactivate "Back release" is identical.
For safety reasons, this function can only be activated or deactivated via the control point in
3 scenarios:
•
•
• After a single power cut, and for the next 4 cycles.
To activate this function:
Position the motorised product at the upper end limit.
1)
Press the my and Down buttons simultaneously until the
2)
motorised product moves.
If the "Back release" function was inactive, it is activated.
If the "Back release" function was active, it is deactivated.
2.3.8. "Closing force" function on cassette awnings only
This function enables the closing force of the awning cassette to be increased or decreased to 3 levels
(high/medium/low).
The motor is factory set at the medium level.
For safety reasons, this function can only be accessed via the control point in 3 scenarios:
•
•
• After a single power cut, and for the next 4 cycles.
To activate this function:
Put the motorised product in the middle position.
1)
2)
then immediately press and hold the my and Up buttons
simultaneously until the motorised product moves.
The motor is in programming mode for just 10 seconds.
Adjust the closing force using the Up or Down buttons.
3)
To increase the closing force, press the Up button until
-
the motorised product moves slowly: the cassette awning
closing force is increased to the upper threshold.
To decrease the closing force, press the Down button until the motorised product moves slowly: the
-
cassette awning closing force is decreased to the lower threshold.
Press the my button until the motorised product moves: the new closing force has been programmed.
4)
Copyright © 2014-
2020 Somfy Activités SA, Société Anonyme. All rights reserved.
-
my and Up buttons simultaneously
1
2
1
2
or
0.5 s
3