EN
2.4. TIPS AND RECOMMENDATIONS FOR INSTALLATION
2.4.1. Questions about the Sunea CSI?
Observations
The motorised product
does not operate.
2.4.2. Replacing a lost or broken Somfy control point
Only switch off the power to the application to be reset.
This reset deletes all the local control points, however the sensors, end limit settings and
favourite position are retained.
Position the motorised product at the mid-height position.
1)
Cut the power supply for 2 seconds.
2)
Switch the power supply back on for 5 to 15 seconds.
3)
Cut the power supply for 2 seconds.
4)
Switch the power supply back on: the motorised product
5)
moves for a few seconds. (If the application is in the upper
or lower limit position, it will make a brief up and down
movement).
Press the PROG button on the new control point until the
6)
motorised product moves up and down: the new control
point is programmed and all the other control points are
deleted.
20
Images not contractually binding Copyright © 2014-
Possible causes
The wiring is incorrect.
The drive is in thermal protection
mode.
The control point battery is low.
The control point is not compatible.
The control point used has not been
programmed into the motor.
Solutions
Check the wiring and modify it if necessary.
Wait until the motor cools down.
Check whether the battery is low and replace it
if necessary.
Check for compatibility and replace the control
point if necessary.
Use a programmed control point or program
this control point.
1
3
5
6
PROG.
2020 Somfy Activités SA, Société Anonyme. All rights reserved.
-
2
OFF
5 s
4
ON
OFF
15 s
ON
2 s
2 s