IMPORTANT: Observe all governing codes and ordinances.
Check the location where the air conditioner will be installed.
Make sure you have everything necessary for correct installation.
The location should provide:
Heat/Cool Models—Grounded electrical outlet within 4 ft
(122 cm) of where the power cord exits the air conditioner.
Cool Only Models—Grounded electrical outlet within 6 ft
(182.9 cm) of where the power cord exits the air conditioner.
NOTE: Do not use an extension cord.
Free movement of air in room to be cooled.
A large enough opening for the air conditioner. Installation
parts are supplied for double-hung windows.
Adequate wall support for weight of air conditioner. Air
conditioner weighs 88 lbs to 100 lbs (40 kg to 45 kg).
NOTE: Cabinet louvers must not be obstructed. Air must be able
to pass freely through the cabinet louvers.
A. Cabinet louvers
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
The electrical ratings for your air conditioner are listed on the
model and serial number label. The model and serial number
label is located on the right-hand side of the air conditioner
cabinet.
4
All manuals and user guides at all-guides.com
Location Requirements
A
Electrical Requirements
Window Installation
Window opening measurements:
22³⁄₄" min. to 32⁵⁄₈" max. (57.8 cm to 82.9 cm) opening width.
15" min. (38.1 cm) opening height.
³⁄₄ " min. (57.8 cm)
A. 22
B. 15" min. (38.1 cm)
Specific electrical requirements are listed in the chart below.
Follow the requirements for the type of plug on the power supply
cord.
Power supply cord
Wiring requirements
Recommended Grounding Method
This air conditioner must be grounded. This air conditioner is
equipped with a power supply cord having a grounded 3 prong
plug. To minimize possible shock hazard, the cord must be
plugged into a mating, grounded 3 prong outlet, grounded in
accordance with all local codes and ordinances. If a mating outlet
is not available, it is the customer's responsibility to have a
properly grounded 3 prong outlet installed by a qualified electrical
installer.
A
B
115-volt (103.5 min. - 126.5 max.)
0-12 amps
15-amp time-delay fuse or
circuit breaker
Use on single outlet circuit only.