Creating A Priority Circuit; Connecting The Remote Control; Connecting The Float - Dometic TEC 29EV Instrucciones De Montaje

Ocultar thumbs Ver también para TEC 29EV:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 69
Connecting the electrical power to the generator
10.7

Creating a priority circuit

You can create a priority circuit using the AG 102 changeover relay whereby
the external voltage supply has priority over the generator, see circuit dia-
gram (fig. f, page 11):
Item
Description
1
230 V external voltage supply
2
Vehicle electrical distribution system
3
Connection box
➤ Mount the AG 102 changeover relay in a suitable position.
➤ Disconnect the cable which links the mains input with the circuit breaker
in the electrical distribution system of the vehicle so that the connections
can be made as shown in the circuit diagram.
➤ Use a flat plug for connecting the cable to the switch.
➤ Connect A with plug-in sleeve 4 and B with plug-in sleeve 6.
➤ Connect the cable from the 230 V connection terminal of the generator to
plug-in sleeve 1 and plug-in sleeve 3.
10.8

Connecting the remote control

➤ Connect the remote control to the connection box of the generator using
the extension cable provided on the plug for the remote control (fig. c 3,
page 9).
10.9

Connecting the float

➤ Connect the float from the tank to the float connection (fig. c 4, page 9).
28
All manuals and user guides at all-guides.com
TEC29EV
EN

Publicidad

Tabla de contenido
loading

Tabla de contenido