9. Specifications
Specifications
Temperature coefficients in rated
temperature range
Mean TC zero point
Mean TC span
EN
Reference conditions (per IEC 61298-1)
Ambient temperature
Atmospheric pressure
Air humidity
Power supply
Mounting position
Operating conditions
Permissible temperature ranges
Medium
Ambient
Storage
Nominal temperature
Air humidity
Vibration resistance
Shock resistance
Service life
Ingress protection (per
IEC 60529)
Mounting position
22
All manuals and user guides at all-guides.com
≤ ±0.16 % of span/10 K
≤ ±0.16 % of span/10 K
15 ... 25 °C [59 ... 77 °F]
950 ... 1,050 mbar [13.78 ... 15.23 psi]
45 ... 75 % r. h.
DC 24 V
Process connection lower mount
Higher values available. For valid values, see order documentation.
-30 ... +100 °C [-22 ... +212 °F] (option: -40 ... +125 °C [-40 ... +257 °F])
Option only for circular connector M12 x 1, metal
-30 ... +85 °C [-22 ... +185 °F] (option:-40 ... +85 °C [-40 ... +185 °F])
Option only for circular connector M12 x 1, metal
-40 ... +70 °C [-40 ... +158 °F]
-20 ... +80 °C [-4 ... +176 °F]
45 ... 75 % r. h.
25 g, 10 ... 2,000 Hz (IEC 60068-2-6, under resonance)
100 g, 6 ms (IEC 60068-2-27, mechanical)
1,000 g, 1 ms (IEC 60068-2-27, mechanical) for electrical connection, M12 x 1 metallic
100 million load cycles (10 million load cycles for measuring ranges > 600 bar/7,500 psi)
see "Electrical connections"
as required
WIKA operating instructions, pressure sensor, model A-1200