Standard Programming (Default); Gate 1 Opening Time; Gate 2 Opening Time; Opening Time Of Pedestrian Gate - V2 PD1 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

All manuals and user guides at all-guides.com
This type of programming allows loading the V2 ELETTRONICA
default program in the memory: the standard data that will be
inserted automatically are shown in the table below (in the
column DEFAULT DATA).
Set the wished function pressing the up or DOWN keys and press
MENU key to confirm.

GATE 1 OPENING TIME

This menu is adjustable from 0 to 120 seconds (±0,5) and
determines the time of opening of gate 1.

GATE 2 OPENING TIME

This menu is adjustable from 0 to 120 seconds (±0,5) and
determines the time of opening of gate 2.

OPENING TIME OF PEDESTRIAN GATE

This menu is adjustable from 0 seconds to t.AP1 (±0,5) and
determines the opening time of pedestrian gate.

CLOSING TIME GATE 1

This menu is adjustable from 0 to 120 seconds (±0,5) which is
the closing time for gate 1.To avoid the uncompleted closing of
the gate, we suggest to set a longer opening time of t.AP1.

CLOSING TIME GATE 2

This menu is adjustable from 0 to 120 seconds (±0.5) which is
the closing time for gate 2. To be sure of the perfect closing of
the gate, we suggest to set a longer opening time t.AP2.

CLOSING OF PEDESTRIAN GATE

This menu is adjustable from 0 to t.Ch1 (±0.5) and determines
the closing time of gate 1. In order to avoid the uncompleted
closing of the gate, we suggest to set a longer opening time of
t.APP.

CLOSING TIME GATE 2 DURING PEDESTRIAN CYCLE

Enables the adjustment from 0 to tChP (±0.5) and determines the
time through which gate 2 will close during the closing phase of
the pedestrian gate.
19

Publicidad

Tabla de contenido
loading

Tabla de contenido