PROGRAMMING THE OPERATIONAL LOGIC
It is possible for the control unit to use several different operational logic states, by simply moving the dip-switches located on the card.
The functions associated with each individual dip-switch are listed below.
DIP
FUNCTION
1
LIGHT
OPERATION
2
LOGIC
START WHILE
3
OPENING
4
DEAD MAN LOGIC
5
PHOTOCELL
6
PRE-FLASHING
SETTING
DESCRIPTION
ON
COURTESY LIGHT
The output (E1 - E2) is on and fixed during opening, pause and closure.
Once the operating cycle is finished, the light stays on for 2 minutes
OFF
FLASHING LIGHT
Output (E1 - E2) is on intermittently (2 Hz) during opening and closing and during
pause mode, if automatic reclosing is active
ON
AUTOMATIC LOGIC
The start command activates an OPEN-PAUSE-CLOSE-STOP operational cycle.
Closure starts automatically after the pause time set (trimmer PAUSE)
OFF
STEP LOGIC
The start command activates an OPEN-STOP-CLOSE-STOP-OPEN
operational cycle
ON
START ACTIVE WHILE OPENING
During opening, the START command interrupts opening (no timer is set for automatic
re-closure)
OFF
START INACTIVE WHILE OPENING
During opening, the START command is ignored
ON
DEAD MAN LOGIC ACTIVE
The user must press and hold the start button for the entire duration of the desired
opening or closing procedure.
The maximum duration of opening or closing depends on the operating time set.
DEAD MAN logic may be implemented with both Start/Stop and Up/Down logic.
The STOP command interrupts the operational cycle, independently of the status of
the control inputs.
Hence, if the START button is pressed, the action of STOP is to stop motion, and on
its release the motor DOES NOT MOVE UNTIL THE START INPUT IS RELEASED AND
PRESSED ONCE MORE
PLEASE NOTE: when the Man-Present function is enabled, radio-controlled
operation is disabled.
OFF
DEAD MAN LOGIC INACTIVE
By simply using the start command, the user can activate the automation device in
opening or closing.
The maximum duration of opening or closing depends on the operating time set
(trimmer WORK).
ON
PHOTOCELL ACTIVE DURING OPENING AND CLOSING
The intervention of the photocell during the opening phase causes the motor to stop.
When the photocell beam is released, the automation starts during opening for the
time set with the WORK trimmer.
The intervention of the photocell during the closing stage causes the shutter to reopen.
OFF
PHOTOCELL ACTIVE ONLY DURING CLOSING
The intervention of the photocell during the opening stage is ignored.
The intervention of the photocell during the closing stage causes the shutter to reopen.
ON
PRE-FLASHING ACTIVATED
Before activating the motor during opening, the flashing light is turned on for 1 sec.
Before activating the motor during closing, the flashing light is turned on for 3 sec.
OFF
PRE-FLASHING NOT ACTIVATED
- 11 -