Descargar Imprimir esta página

Safety Instructions - Waeco CAB-40 Manual Del Usuario

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 16
manual 4445100023_a.qxd

Safety instructions

• Please check the proper condition of the appliance before use.
• Before starting up the device the instruction manual should be read thoroughly!
• During first hours of operatin the appliance might develop some smell.
• The device should only be driven by one power source at a time.
GB
• The cooling system must not get damaged!
• No electrical devices are allowed inside of the cooling box!
• If the supply cord is damaged it must be replaced by the manufacturer, its service
agent or similar qualified person in order to avoid a safety hazard.
General
Installation
This appliance is suitable for camping use.
The cooling box may only be used in well ventilated places. It must be protected
against rain and splash water. To obtain best efficiency the coolbox has to be
positioned on a level surface. The horizontal position ±2° should if needed be
checked using a water level. The ventilation grill on the top, bottom and backside of
the device must always be kept clear. Please note the minimum clearance at the
lateral limitation of at least 5 cm.
Control panel
This is located at the right backside of the device and is protected by a lid.
Here are:
• The thermostat control for the supply with 230 V AC
• The control element for the gas supply with the positions: max., min., closed
• The press button for the burner ignitor
Gas operation
The device is not allowed to be operated by gas when used in road vehicles,
water crafts or inside closed spaces! Enough air supply has to be obtained for
the usage in tents and on ground level terraces. Do not assemble the device
close to inflammable materials (paper, dry leaves, textiles).
Connection onto a gas source
The device may only be run by a pressure specified on the specifications plate (back
side)!
• Use a propane- butane gas bottle with proven pressure control valve.
• Check that the gas bottle valve is closed.
• Use a proven hosepipe (DIN 4815 Part 2) of max. 1.5 m length.
• Connect the gas line to the inlet port of the fridge from the regulator. For this use the
correct spanner size, please note this has left hand thread.
• Open bottle valve and check all connections with lead detector spray. Density is
only guaranteed, if no air bubbles develop. Never carry out the density check close
to fire or ignition sources!
• Make sure gas bottle is always set upright and at least one meter away from the
burner. Prove that the gas line is not pinched or kinked.
09.11.2004
15:59
All manuals and user guides at all-guides.com
(fig.1, 3)
Seite 6
(fig.1, 2)
6
(fig.1, page 1)
(fig.1, 1)

Publicidad

loading

Este manual también es adecuado para:

Ca-4044000-02Cab-55