2. FOUNDATION PLATE ANCHORAGE
To install the foundation plate it is necessary to:
2.1. Prepare a concret basement with the dimensions shown
in Fig. 1 where the foundation plate and the anchor bolts will
be concreted.
NOTE: It is recommended, gate structure permitting, to lift the
foundation plate about 50mm from the ground, in order to
avoid eventual water stagnation (Fig.1)
Fig. 1
2.2. Before concreting in the plate insert a flexible plastic duct
35 mm minimum)
into the special hole of the plate.
2.3. Before concreting in the plate, make sure that it is perfelcty
leveled and that the distance of 50-55mm as shown in Fig. 2 is
respected.
58-67
3. CABLES PASSAGE ARRANGEMENT
Saturn is provided with two different holes for electric cables
passage.
It's very important to make the high - tension (230Vac) cables
pass through one hole and the low - tension cables (24Vdc)
through the other one (Fig. 3)
cod. 67410326
®
MINIMUN DIMENSION Q
Z16
108 mm
Z20
116 mm
43-58
Fig. 3
Hole 1
Hole 2
4. FITTING OF THE MOTOR REDUCER
4.1. Insert the 4 grains into the special holes, so that it is
possible to adjust the motor reducer height on the plate (Fig. 4).
4.2. Fix the motor reducer to the foundation plate with the 2
included nuts, adjusting the side position (Fig. 5) so to respect
the shown quota in (Fig. 2).
Plinto
4.3. Remove the closing loading oil cap (red) and substitute
it with that supplied apart provided with the airhole (black).
Ø
Fig. 2
REV 01 - 07/2008
Fig. 4
Fig. 5
10/33