6
Safety Notes
6 Gloves should be worn during installation to prevent
crushing and cutting injuries.
Installation Instructions
• The fitting must be installed, flushed and tested after
the valid norms!
• Important!* With water heaters of 5 liters the flow rate
at the mixer should not exceed 5 l/min. In this case the
flow rate must be reduced at the isolation valve.
Technical Data
Operating pressure:
Recommended operating pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Rate of flow:
anti-pollution function
Fault
Insufficient water
Mixer stiff
Mixer dripping constantly with water
heater switched off
Water escaping in area of swivel
spout
Water escaping at the threaded base - Adapter floor leaks
Water escaping bels ow handle
Water run out below the skin
4
English
Symbol description
max. 1 MPa
0,1 – 0,5MPa
max. 80°C
65°C
max. 5 l/min
Cause
- Spray former calcified, dirty
- Filter at the isolation valves soils.
- Cartridge defective, calcified
- Cartridge defective
- O-ring defective
- O-ring at the connection hose
defective.
- Cartridge defective
- The connection of the hanspray is
not tighten
- Hose have a defect
Assembly see page 31
Do not use silicone containing acetic acid!
Dimensions (see page 33)
Test certificate (see page _1u)
Spare parts (see page 35)
Operation (see page 34)
When the storage tank is being heated, the
spout will drip.
Cleaning (see enclosed brochure.)
Maintenance (see page 36)
• The non return valves must be checked
regularly according to DIN EN 1717 in
accordance with national or regional
regulations (at least once a year).
• When changing the spray former, it is
imperative to use one made for this type
of mixer.
Remedy
- Clean spray former, exchanging if
necessary
- Clean the filter / exchange filter
- Exchange cartridge
- Exchange cartridge
- Exchange O-ring
- Check the adapter floor, replace if
necessary
- Exchange O-ring
- Exchange cartridge
- Tighten the connection
- Exchange the hose