1) Cut off power supply.
2) Manually release the door and push it for about half stoke. Lock the door again.
3) Restore power supply.
4) Send a step-by-step control through P2 push-button, P.P. input or radio-control signal.
5) The door must move in the opening phase. In the negative, with motor stopped, it is sufficient
to invert the motor and limit switch (MOT/MOT) wires (SWO/SWC).
6) Proceed by adjusting Times and operating Logics.
Dip-
Function
Switches
DIP1
Torque
adjustment /
radio
learning
DIP2
Bloc of flats
DIP3
TCA Special
DIP4
P.P. : operating
mode
DIP5
Radio channel II
/LOCK
DIP6
Step-by-Step:
3-STEP
mode
HOW TO CHECK CONNECTIONS:
DIP-SWITCH FUNCTION
Description
It is possible to switch between the torque adjustment mode
and the radio learning.
Off: RADIO LEARNING mode (see section "Radio learning")
On: TORQUE ADJUSTMENT mode (see section "Torque
Regulation").
The bloc of flat function is enabled or disabled.
Off: the bloc of flat function is disabled.
On: the bloc of flat function is enabled.
The Step-by-Step signal or the transmitter signal has no effect
during opening.
The TCA special is enabled or disabled.
Off: Special TCA function is disabled.
On: Special TCA function is enabled.
If a PP control signal is sent in the first 5 seconds of the TCA
calculation, the TCA is ignored and the closing operation is
started.
If the PP control signal is sent after the first 5 seconds and
before the preset TCA time has elapsed, the time is reset and
the new TCA counting starts.
The operating mode of the "P.P. button" and of the transmitter
is selected.
Off: Operation: OPEN>STOP>CLOSE>STOP>
On: Operation: OPEN>CLOSE>OPEN>
The operating mode of the output to SCA terminals is selected
(for a correct operation of the logics see the table "Inputs/
outputs functions – SCA-SCA paragraph" at page 4).
Off: Impulse output for the control of the Lock card for electric
lock
On: Impulse output, radio channel II of the incorporated
receiver
The 3 steps is enabled or disabled.
On: The PP control sequence is the following:
OPEN>STOP>CLOSE>OPEN>STOP>CLOSE>...
Off: The control sequence is the one preset by DIP 4.
NOTE: it operates with DIP 4 only on OFF.
9