Intended Use; Commissioning; Connecting The Mobile Dust Extractor; Connecting A Power Tool - Festool CTL MINI I Manual De Instrucciones Original

Ocultar thumbs Ver también para CTL MINI I:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 29
mobile dust extractor
Equivalent Isotropically Radiated Power (EIRP)
Container capacity
Dimensions L x W x H
Weight
5

Intended use

Mobile dust extractor suitable for
extracting dust up to 1 mg/m³ according to
dust class L,
extracting water,
for increased loads during commercial use,
according to IEC/EN 60335-2-69.
The user is liable for improper or non-in­
tended use.
6

Commissioning

WARNING
Unauthorised voltage or frequency!
Risk of accidents
► Observe the specifications on the ma­
chine's name plate.
► Observe country-specific regulations.
6.1
Initial commissioning
► Insert the filter/disposal bag [2].
► Fit the cord holder [3].
► Connect the suction hose [3].
6.2

Connecting the mobile dust extractor

WARNING
Risk of injury from uncontrolled tool start-
up
► Before switching on ensure that the con­
nected tool is switched off.
WARNING
Risk of injury from electric current
► Insert the mains plug into an earthed sock­
et.
► Do not reach into the electrical outlet mod­
ule on the mobile dust extractor.
CTL MINI I
CTL MIDI I
CTL MINI I
CTL MIDI I
CTL MINI I
CTL MIDI I
While the mobile dust extractor is connec­
ted to the mains socket, an electric cur­
rent is running through electrical outlet
module on the mobile dust extractor at all
times.
Connecting the mobile dust extractor to a
mains socket
The mobile dust extractor is switched off.
► Connect the power cable to a mains socket.
The electrical outlet module [1-2] is live.
Switching the mobile dust extractor to standby
mode
► Press the on/off switch[1-11].
The electrical outlet module [1-2] is live.
The green LED [1-18] indicates standby
mode.
Starting the mobile dust extractor automati­
cally
The mobile dust extractor is in standby mode.
► To start the mobile dust extractor automati­
cally: Switch on the connected tool.
Starting the mobile dust extractor manually
The mobile dust extractor is in standby mode.
► Press the MAN button [1-17].
Pull the mains plug from the socket when
you are not using the mobile dust extrac­
tor and before performing any cleaning and
maintenance work.
6.3

Connecting a power tool

WARNING
Risk of injury
► Observe the maximum electrical outlet
module connected load (see chapter
"Technical data").
► Switch off the power tool.
English
< 10 dBm
10 l
15 l
470 × 320 × 455 mm
470 x 320 x 495 mm
11.0 kg
11.3 kg
17

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ctl midi iCtl miniCtl midi

Tabla de contenido