Dc Voltage Measurement; Measuring Ac Current - Metrix MX 655 Manual De Instrucciones

Pinza multímetrica
Ocultar thumbs Ver también para MX 655:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

4.2. DC voltage measurement

600
1000
PE AK
1 m S
HOLD
A
10 00
V
40 0
40
Hz
REL
600
75 0
1 00 0
60 0V

4.3. Measuring AC current

(MX 650) Set the switch to
1000 A~ and 400 A~ automatic calibres).
(MX 655) Set the switch to 1000 A
(alternating signal) should be displayed. If not, press on the
/
button, to make it appear.
Open the clamp jaws by pressing the trigger. Position the
clamp around the conductor to be measured.
Release the trigger. Check the clamp is properly closed. Read
the result of the measurement on the display.
If reading is difficult, press the HOLD button and read the
result afterwards.
If necessary, for better resolution you can move to a lower
range by means of the selector switch.
Note: For safety reasons, disconnect the measuring leads
before measuring current. The clamp should encircle only one
conductor, otherwise the measurement result may be
incorrect. The best measurement is obtained with the
conductor centred in the middle of the jaws.
24
Chapter II
(MX 650) Set the
switch to
V.
(MX 655) Set the
switch to
V.
Press on the
/
button
to display the
symbol
(direct signal).
Connect the red test lead
to the "+" input terminal
and the black test lead to
the "COM" input terminal.
Then place the touch prods
in contact with the points
where the DC voltage is to
be measured.
Then read the result on the
display.
A (corresponding to the
. The
symbol
MX 650 / MX 655