AEG Electrolux SANTO 75428-2 DT Manual De Instrucciones página 22

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Malfunction
The food is too warm.
Interior lighting does not
work.
Heavy build up of frost, possi-
bly also on the door seal.
Unusual noises.
The compressor does not start
immediately after changing
the temperature setting.
Water on the floor or on sto-
rage shelves.
22
All manuals and user guides at all-guides.com
Possible Cause
Temperature is not properly
adjusted.
Door was open for an exten-
ded period.
A large quantity of warm
food was placed in the
appliance within the last 24
hours.
The appliance is near a heat
source.
Light bulb is defective.
Door seal is not air tight (pos-
sibly after changing over the
hinges).
Appliance is not level.
The appliance is touching the
wall or other objects.
A component, e.g. a pipe, on
the rear of the appliance is
touching another part of the
appliance or the wall.
This is normal, no error has
occurred.
Water drain hole is blocked.
Remedy
Please look in the "Initial Start
Up" section.
Open the door only as long as
necessary.
Turn the temperature regula-
tor to a colder setting tempo-
rarily.
Please look in the "Installation
location" section.
Please look in the "Changing
the Light Bulb" section.
Carefully warm the leaking
sections of the door seal with
a hair dryer (not hotter than
approx. 50 °C). At the same
time shape the warmed door
seal by hand such that it sits
correctly.
Readjust the feet.
Move the appliance slightly.
If necessary, carefully bend
the component out of the
way.
The compressor starts after a
period of time.
See the "Cleaning and Care"
section.

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido