Typical Installations; Installation Steps - NuTone QT DC Serie Instrucciones De Montaje

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Housing
mounted to
I-joists.
Use I-joist
spacer block
(provided).
Housing
mounted
anywhere
between
I-joists
using
hanger bars.
Housing
mounted to
joists.
Some models only:
1 1
Select 110, 130 or 150
CFM based on your
room size and
desired
air flow.
Screws from
Plug-in and
1 2
secure blower
to housing.
All manuals and user guides at all-guides.com

TYPICAL INSTALLATIONS

INSTALLATION STEPS

110 130 150
2
parts bag
Housing
mounted
anywhere
between
joists
using
hanger bars.
Housing
mounted to
truss.
Housing mounted
anywhere between
trusses using
hanger bars.
Mount housing to joist.
3a
1
Hold housing in place so
that bottom edge of housing
will be flush with finished
surface of ceiling. For
1/2" thick ceiling material,
position bottom of each
mounting flange flush with
the bottom of joist. The
housing mounts with four
(4) screws or nails. Screw or nail housing to joist through lowest
holes in each mounting flange, then through highest holes.
1
NOTE: Mounting to I-JOIST (shown) requires use of SPACERS
(included) between the highest hole of each mounting flange and
the I-joist.
2
SPACER
(use for
mounting
to I-Joist)
I-JOIST
OR

Publicidad

Tabla de contenido
loading