Extraordinary Maintenance; End Of Service Life; Replacement Parts; Anomalies - Causes - Solutions - Senco AC33024 Instrucciones De Empleo

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 57
EN
STANDARD MAINTENANCE TABLE
FREQUENCY
INTERVENTION
AREA
ONCE A DAY
Safety
devices.
Electrical
cable and
plug.
Tank.
EVERY WEEK
Wheels.
N. 2 air filters.
Back view
INTERVENTION TYPE
Ensure they are intact, correct-
ly installed and functioning.
Visual check of usage status.
Upon termination of each
work cycle, rest the appliance
on the ground and drain the
tank condensate pump open-
ing the condensate pump (A).
Wheel pressure check.
Subsequently pump up with
compressed air up to a maxi-
mum of 2.5 bar.
Unscrew the screws (1).
Remove the cover (2).
Extract the filter (3) and clean
it using compressed air.
Correctly replace the cover.
NOTE: REPLACE IN THE IN-
STANCE WHERE IT IS WORN.
A
2
3
2
1

26. EXTRAORDINARY MAINTENANCE

All activities carried out to ensure use and operation of the
appliance, via various intervention types (regulation, valve
checks, cleaning of air filters, etc.) executed by the Manufactur-
er's technicians according to preestablished time intervals and
in the instance of faults or wear and tear.
IN THE INSTANCE OF EXTRAORDINARY MAINTE-
NANCE, TECHNICAL ASSISSTANCE PROVIDED BY THE
MANUFACTURER OR THE AUTHORISED SUPPLIER
MUST BE REQUESTED.

27. END OF SERVICE LIFE

When disposing of the appliance, current legislation in force
must be considered.
Dispose of the various component materials separately (plastic,
copper, iron, etc.).

28. REPLACEMENT PARTS

IN THE INSTANCE OF EXTRAORDINARY MAINTE-
NANCE, TECHNICAL ASSISSTANCE PROVIDED BY THE
MANUFACTURER OR THE AUTHORISED SUPPLIER
MUST BE REQUESTED.
USING UNORIGINAL REPLACEMENT PARTS IS FORBIDDEN.

29. ANOMALIES - CAUSES - SOLUTIONS

The following table displays various scenarios which may occur
when using the appliance.
AUTHORISED OPERATORS MUST ONLY CARRY OUT
OPERATIONS FOR WHICH THEY ARE QUALIFIED (SEE
PARAGRAPH 2) AND WITH THE CONSENT OF THE
SAFETY MANAGER (WHERE THE APPLIANCE IS USED IN A
BUSINESS CONTEXT).
ABNORMALITIES
CAUSE
The appli-
No electrical
ance will not
supply.
start or it
stops and will
not re-start.
Intervention
of thermal
reset owing to
voltage over-
load and/or a
short-circuit.
10
SOLUTION
• Check that the "ON-
OFF" switch (3) is in the
"ON (I)" position.
• Check that the electri-
cal plug is functioning
correctly and is cor-
rectly plugged in.
• Check that any exten-
sions used and the
plug are functioning
correctly.
• Check that the elec-
trical main switch is
functioning and in the
"ON" position.
• Carry out the pro-
cedure described in
Paragraph 22.